Description Of The Connections - Nice Mindy A6 Instrucciones Y Advertencias Para El Instalador

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 58
4

3.4) Description of the connections

Here is a brief description of the possible connections of the unit to the outside:
1...3
: 230 - 120 Vac
4-5
: Flashing light
6...8
: Motor 1
9...11
: Motor 2
Note: Motors 1 and 2 only differ in the start delay; the 1st motor is connected to the opening delay time "TRA" while the 2nd motor is con-
nected to the closing delay time "TRC". If the delays are unnecessary there is no difference between the motors.
The following terminals are found only on the A700F and A6F version:
12-13
: Electric lock
You will find the following terminals only on the A700F version:
14-15
: Phototest
16
: Common
17
: C1 limit switch
18
: A1 limit switch
19
: C2 limit switch
20
: A2 limit switch
21-22
: 24 Vac
23
: Common
24
: Gate Open Indicator
25
: Stop
26
: Photocell
27
: Photocell 1
28
: Step-by-Step
You will find the following terminals only on the A700F version:
29
: Open
30
: Close
41-42
: 2° Radio Ch
43-44
: Antenna
There are an additional two slots on the unit card for optional cards:
RADIO
= Slot for Nice radio receivers
PIU
= Slot for PIU' expansion card (only on the A700F version)
We recommend waiting until installation is complete to plug in the optional cards RADIO or PIU' and only after having checked that the sys-
tem is working properly. The optional cards are not necessary for the working of the system and if they are used they make troubleshooting
more complex.
FUNCTIONS 1-10
= Output for connection to the 230 -120 Vac flashing light, maximum lamp power 100 W
= Output for connection to the 1st motor 230 - 120 Vac
= Output for connection to the 2nd motor 230 - 120 Vac
= 12 Vac output to activate the electric lock, 25 W maximum power
= 24 Vac output to feed photoelectric cell transmitters, 100 mA max.
= Common for limit switch inputs (same as the other common, terminal 23)
= Close limit switch input for motor 1
= Open limit switch input for motor 1
= Close limit switch input for motor 2
= Open limit switch input for motor 2
= 24 Vac output to feed accessories (Photocell, Radio, etc.) 200 mA max.
= Common for all inputs (terminal 22 can also be used as Common
= 24 Vac output for gate open indicator, 2 W max. indicator power
= Input with STOP function (Emergency, shutdown or extreme safety)
= Input for safety devices (photoelectric cells, pneumatic edges)
= Input for another safety device (photoelectric cells, pneumatic edges)
= Input for cyclic functioning (OPEN STOP CLOSE STOP)
= Input for opening (it can be controlled by a timer)
= Input for closing
= Output for the second radio receiver channel if there is one
= Input for the radio receiver antenna
Antenna
2° Radio
Ch
FUNCTIONS 11-20
The highlighted part is only found on
the A700F version.
The highlighted part is found on the
A6F and A700F versions.
GB
7

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Mindy a6fMindy a700f

Tabla de contenido