4.3
Description
4.4
Typical
applications
Description
Rugby 260SG / 270SG / 280DG, Operation

Rugby 260SG Used at Grade

If the Rugby 260SG is used at grade it self-levels at the
desired grade.
When the accurate grade value is reached, grade is locked and
self-levelling turned off.
As self-levelling is turned off, no compensation for
any external setup and grade changes is applied.
However, if the Rugby is subsequently disturbed or knocked, the H.I. alert occurs, if
active, to indicate sudden changes.
The Rugby 270SG / 280DG are fully self-levelling lasers, hence will always self level at
grade to compensate for any external setup and grade changes.

Lay Down Mode

The lay down mode is only available on the Rugby 280DG.
Lay down of 90° angles, plumb (tilt-up walls) and transferring points from the floor
to the ceiling.
In lay down mode the beam goes automatically to the beam down position (0 rps) so
that the Rugby can be aligned over a reference point.