FILTER CARTRIDGES IN THE CANOPY PART
Figure 31
Page
Fold down the canopy pane.
41
㉕
Open the retaining clamp of the cartridge.
⇒
Remove the filter insert.
When installing the insert, make sure that the
honeycomb grill is directed towards the inside.
Canopy drive
10/13
4
PH2
Service the wire ropes after
each tube replacement in order
to guarantee a trouble-free
operation of the drive.
SERVICING THE CANOPY DRIVE
Test the canopy drive. The canopy must lock
⇒
in place in all positions. If it does not, the can-
opy springs must be tensioned ㉗ ㊳.
Check the ropes of the canopy drive. Should
⇒
individual wires be frayed, replace the rope
immediately.
Grease the rope in the area of the return pulley
⇒
with copper crease or adhesive lubricant
HHS-2000 (KBL 1200024000).
㉕
PH2
19
↵
REPLACING THE SPRING-LOADED WIRE ROPES
(PREPARATION)
㉖
Page
Open the bench part.
40
Disconnect the cable connections of the
㉖
audio system (only on right-hand side).
Pay attention to the correct connections
according to the colours ㉖ during the
subsequent assembly.
⇒
Close the bench.
ⓐ
Figure 33
ⓑ
㉗
Remove the foot panel and undo the cable of
㉗
the decorative lighting ㉘.
Figure 34
㉙
㉙
Remove the side panel -> pull forward ㉙.
M a n u a l d e i n s t r u c c i o n e s | megaSun 7900
Figure 32
㉘
α
lpha
47