SERVICING THE VENTILATION SYSTEM
⇒
Check all hose connections.
Remove any kinks in the air hoses. Replace
⇒
defective hoses immediately.
The exhaust air hose must not exceed a
maximum length of 6 m if there is no auxiliary
fan installed.
CHECKING THE CONDENSATE PUMP
The condensate pump ㊷ pumps away the
condensation water at timer-controlled intervals.
Check the function of this pump with each tube
replacement.
Fill some water into the condensate tray ㊸.
⇒
Use a hose and a funnel to do so.
Make sure that the water does not spill over.
Start a tanning session and then wait for 20
⇒
minutes.
The filling level of the tray must then be below
⇒
the pump level.
50
M a n u a l d e i n s t r u c c i o n e s | megaSun 7900
EMPTYING THE CONDENSATE TANK
The condensate pump transports the condensation
water into a canister via a hose. Once this condensate
canister is full, a corresponding message is displayed.
The air-conditioning symbol flashes (check), and the
air-conditioning unit switches off shortly afterwards.
Figure 42
Unscrew the closing lid of the condensate
㊹
canister.
㊺
Empty the condensate canister.
When closing, make sure that the condensate
hose is inserted a max. of 50 mm into the
canister.
Finally, acknowledge the aircon message on
⇒
the display (START).
Recording to an SD card
REMOVING THE SD CARD
The audio module is located in the control box at
the foot end of the base part of the sunbed. This
module comprises the SD-card slot which contains
the storage medium of the MP3 data of the internal
MP3 player.
α
lpha
㊺
㊹
↵