REPLACING THE SPRING-LOADED WIRE ROPES
Figure 40
㊲
19
㊳
㊲
Involve a second person to secure the canopy
against falling down.
Remember the position of the nut at the
㊳
spring tensioner. Then slacken the spring
using a pipe wrench SW19.
㊴
Undo the upper rope holder SW13.
⇒
Replace the wire rope. Fix and tension it.
Grease the rope in the area of the return pulley
㊵
with copper crease or adhesive lubricant
HHS-2000.
13
㊴
㊵
Ventilation and air-conditioning
↵
In order to preserve the performance of the air-con-
ditioning unit, clean the heat exchangers after
500 - 600 hours of operation.
Figure 41
Air-conditioning unit
㊸
㊶
Heat exchanger
㊷
Condensate pump
㊸
Condensate tray
Page
Open the bench part.
40
㊶
Clean the heat exchanger.
Vacuum it carefully, paying attention not to
damage the fins.