Battery Replacement cont'd
NOTE: When reinstalling screws and filter outlet
nut, insert into hole, turn counter clockwise with
screwdriver until a click is felt then turn
clockwise until snug. DO NOT OVERTIGHTEN!
11. Reinstall 2 short and 1 long upper housing screws until snug. Refer to picture
(7&11) on previous page for placement of long screw. DO NOT OVERTIGHTEN!
NOTE: To assist in aligning lower housing, press side buttons
slightly while sliding housing in place.
12. Reinstall lower housing by carefully aligning over button covers.
13. Reinstall two short lower housing screws until snug. DO NOT OVERTIGHTEN!
14. Reinstall filter outlet nut (20) with flat screwdriver. DO NOT OVERTIGHTEN!
15. Insert filter by aligning outlet tubes with inlet ports on pullout spout and
gently pushing in and down. Upon successful installation of filter cartridge,
the filter life indicator will emit a series of three beeps and will reset
automatically.
16. Reinstall filter cover by positioning alignment
tab over corresponding notch in pullout spout
and gently pushing in and down.
17. Reattach quarter turn connector (18) to pullout
spout (19) aligning the dots on the quarter
turn connector and the spout. Push the quarter
turn connector onto the spout and turn it
clockwise, locking it in place. Return spout to the
receptor.
18. If new filter was not installed at battery change, refer
to remaining filter life previously recorded at
beginning of battery replacement. Subtract recorded
number in step 1 from the 100% displayed. The
difference represents the display setting at which the
current filter will need replacement. Filter may not
perform as desired after this calculation percentage.
Example: Remaining filter life prior to battery change equals 30%.
Subtract 30% from 100% (100 - 30 = 70).
Filter will need to be changed when indicator reads 70%.
INS139
HELPLINE: 1-800-BUY-MOEN
(8)
ALIGN
DOTS
(16)
(17)
12