6.4.1 Condense drain connections
Condensate that forms during the operation of the heat
pump flows through an appropriate discharge pipe
(G 1/2") that passes inside cladding and it comes out on
the side of the equipment.
This must be connected to a duct via a siphon so that
the condensate can flow freely (Fig. 9a or Fig. 9b).
Ø20
≥ 60
Fig. 9a – Examples of condensate drain connection
via siphon
G ½"
≥ 60
Fig. 9b – Example of condensate drain connection
using siphon with water interceptor
Page 20
6.5
Solar power system
integration
The following illustration (Fig. 10) shows an example of
solar power system integration.
Cold water intake pipe
Solar power system pump and accessories
Solar collectors
Heat pump
Recirculation pump
Spring check valve
Drain tap
Solar thermal power coil
Hot water outlet pipe
Fig. 10 – Example of solar power system integration