To change the minutes:
Press and release the
key while changing the
time: the display will show "nn" followed by the two
numbers representing the minutes;
Press and release either the
within 15 seconds;
Press and release the
key or do not carry out
any operations for 15 seconds;
To exit the procedure:
Press and release the
key until the display
shows the temperature established by parameter
P5 or do not carry out any operations for 60
seconds.
Alternatively:
Press and release the
key.
To set operations within timeslots, it is
necessary to have carried out the settings
relating to the day and the real time
beforehand.
8.1.3.15 Configuration parameter settings
To carry out the procedure:
Make sure that the keyboard is not locked
(paragraph 8.1.3.3) and that no other advanced
procedure is in progress;
Keep the
and the
keys pressed for
4 seconds: the display will show "PA" (password);
Press and release the
key;
Press and release either the
within 15 seconds to set "-19" on the display;
Press and release the
key or do not carry out
any other operations for 15 seconds;
Keep the
and the
keys pressed for
4 seconds: the display will show the first
parameter "SP1".
To select a parameter:
Press and release either the
To change a parameter:
Press and release the
key;
Press either the
or the
increase or reduce the parameter value (within 15
seconds);
Press and release the
key or do not carry out
any operations for 15 seconds.
To exit the procedure:
Keep the
and the
keys pressed for 4
seconds or do not carry out any operations for 60
seconds (any changes will be saved).
Switch the equipment off and then back on
again to make the changes made to the
parameters effective.
Installation and user manual
8.1.3.16 Restoring default factory settings
To carry out the procedure:
Ensure that the keyboard is not locked (paragraph
8.1.3.3) and that no other advanced procedure is
or the
key
in progress;
Keep the
4 seconds: the display will show "PA" (password);
Press and release the
Press and release either the
within 15 seconds to set "149";
Press and release the
any operations for 15 seconds;
Keep the
the display will show "dEF";
Press and release the
Press and release either the
15 seconds to set "1";
Press and release the
any other operations for 15 seconds: the display
will show "dEF" flashing for 4 seconds, after which
the equipment will exit the procedure;
Disconnect the equipment from the mains power
supply.
To exit the procedure before its completion:
Keep the
4 seconds during the procedure (or rather before
setting "1": the restoring of default factory settings
will not be carried out).
or the
key
8.1.3.17 TOTAL OF THE COMPRESSOR
8.1.3.17.1
The equipment is capable of memorising up to 9,999
compressor operating hours, if the number of hours
exceeds "9,999" it flashes.
or the
key.
8.1.3.17.2
Make sure that the keyboard is not locked
(paragraph 8.1.3.3) and that no other advanced
procedure is in progress;
key to either
Press and release the
show "Pb1";
Press and release either the
select "CH";
Press and release the
To exit the procedure:
Press and release the
any other operation for 60 seconds.
Alternatively:
Press and release the
and the
keys pressed for
key;
or the
key or do not carry out
and the
pressed for 4 seconds:
key;
or the
key or do not carry out
and the
key pressed for
OPERATING HOURS

General information

Display of compressor operating hours
key: the display will
or the
key.
key or do not carry out
key.
key
within
key to
Page 29