ELECTRICAL SPECIFICATIONS

Accuracy is given as ± (% of reading + counts of least
significant digit) at 23 °C ± 2 °C (≤ 80% R.H.)
AC Function
• AC A specifications are AC coupled, true RMS.
• For non-sinusoidal waveforms, Additional Accuracy by
Crest Factor (C.F.):
Add 1.0% for C.F. 1.0 to 2.0
Add 2.5% for C.F. 2.0 to 2.5
Add 4.0% for C.F. 2.5 to 3.0
• Max. Crest Factor of Input Signal:
3.0 @ 3000 counts
2.0 @ 4500 counts
1.5 @ 6000 counts
• Frequency Response is specified for sine waveform.
• When operating under magnetic field add error E11.
• When measuring leakage current of multiple conductors,
add error E12 for influence of load current.
• For Position Error see error E1.
10 A/m: add ±0.1 mA
30 A/m: add ±0.3 mA
@ I
: 3.500 mA – 600.0 mA / 40 Hz
N
to 1 kHz
and a frequency of the magnetic
field of 15 to 400 Hz acc. to
IEC 61000-4-8
Add ±6 μA per A load current
N/A
N/A
N/A
Two 1.5 V AAA (LR03) batteries
60 hours typical
Approx. 2.5 V
Idle for 20 minutes
8.7 x 3.5x 1.8 in
(221 x 89 x 48 mm)
Approximately 0.90 lb (410 g) with
battery installed