3. CUSTOM HOOD PREPARATION (
To minimize the gap around the power pack, take actual width and depth
measurements of power pack and add 1/16" to get D and E measurements. Cut
the hole in the bottom of the cabinet according to dimensions. See chart and
illustration for details.
P
P
OWER
ACK
M
ODELS
CP34 & CP35
CP37
4. MOUNT CUSTOM HOOD INTERNAL FRAMEWORK
The framework must be positively secured to wall studs or other wooden framework behind the drywall.
Make sure it is capable of supporting its own weight and the weight of the CP34, CP35 or CP37. Failure to
do so may cause personal injury or damage to countertop or cooktop.
The CP34, CP35 and CP37 power pack models are supported by the custom hood internal framework with screws provided in
parts bag.
Since the CP34, CP35 and CP37 power pack models mounting holes are
located in front and rear sides (see illustration beside), plan to install wood frame
at front and sides for support.
5. REMOVE FILTERS
Remove tape on filters. Remove filters from power pack and set aside.
NOTE: It is recommended to start with the center one(s).
CONTINUED
C
D
UTOUT
IMENSIONS
W
IDTH
D
30"
19
3
⁄
"
8
36"
19
3
⁄
"
8
42"
19
⁄
"
3
8
48"
22
⁄
"
5
8
!
)
E
28 ½"
34 ½"
40 ½"
46 ½"
WARNING
- 5 -
E
HD0367
HH0102A
HD0295
D