Tank Connections
Connect the tank up with good quality reinforced
hose. Avoid sharp kinks and sags in the hose.
Bracket the hose at not too far apart, regular points,
to prevent the hose sagging. Deposits will collect in
these sags, causing a blockage after time.
The reinforced hose should be an odour-proof
waste water hose and resistant to a limited under-
and over-pressure of 0.3 bar (0.3 kgf/cm
Vetus supplies a hose suitable for waste water.
Article Code:
WWHOSE08, waste water hose, 8 mm (
nal diameter
WWHOSE16, waste water hose, 16 mm (
nal diameter
WWHOSE19, waste water hose, 19 mm (
nal diameter
WWHOSE25, waste water hose, 25 mm (1") inter-
nal diameter
WWHOSE38, waste water hose, 38 mm (1
internal diameter
WWHOSE45, waste water hose, 45 mm (1
internal diameter
Specially for black water tanks:
SAHOSE25, odour-proof waste water hose, 25-mm
(1") internal diameter
SAHOSE38, odour-proof waste water hose, 38-mm
(1
∕
") internal diameter.
1
2
Fit every hose connection with a good stainless
steel hose clip.
Install pump '10' and hull outlet with valve '12'.
Install the suction hose '17' (38 mm (1
such that neither the tank or pump are subject to
any mechanical loads.
Fit the air-relief nipple '14' maximum 1.5 m above
the level of the top of the tank. Choose a place for
the nipple where rain or other outside water cannot
enter.
If required, fit an odour filter '15' between the air-
relief pipe and nipple.
Fit the air-relief pipe '18', internal diameter 16-mm
(
∕
"), between the air-relief nipple and the tank.
5
8
When viewed from the tank, the air-relief pipe
should run straight upwards.
Discharge pump '10'
A non-priming waste water pump must be fitted lower than, or
at the same height as the underside of the tank.
A self-priming pump can be mounted at any height in relation
to the tank.
Install a bend ventilator '11' in the discharge pipe between
pump and hull outlet when the waste water tank is below the
water line and the hull outlet is also below the water line.
Flexible Waste Water Tanks for grey water and black water
'Grey Water' System
2
, 4 psi).
∕
") inter-
5
1 6
∕
") inter-
5
8
∕
") inter-
3
4
'Black Water' System
∕
")
1
2
∕
")
3
4
1 Grey water tank
2 Black water tank
3 Inlet connections
/
") dia.)
1
2
- Grey water tanks: 16, 25, 35
and 38 mm dia.
- Black water tanks: 38 mm dia.
4 Suction connector 38 mm dia.
5 Air-relief connector: 16 mm dia.
6 Wash basin
7 Shower
8 S-bend (stink trap)
9 Toilet
10 Waste water pump
Rinsing pipe
In order to rinse out the tank easily with clean water, and extra
fitting can be made in the deck connected to an extra deck cap.
Clean water can be poured in through this pipe.
ENGLISH
11 Bend ventilator
12 Hull outlet with valve
13 Hull outlet, 8 mm diameter
14 Air-relief nipple
15 Odour filter
16 Inlet waste water hose
- Grey water tanks: 16, 25, 35
and 38 mm dia.
- Black water tanks: 38 mm dia.
17 Suction waste water hose: 38 mm
dia
18 Air-relief pipe: 16, 25 mm dia.
19 Ventilator pipe: 8 mm dia.
110106.04