Preparation for winter
The tank, pipes, pump, etc., should always be drained.
Never add anti-freeze to the tank or other parts of the waste
water system to protect against frost damage. Anti-freeze is
very poisonous!
Clean the tank according to the cleaning procedure.
Maintenance
Regularly check the air-relief nipple and clean its sieve if neces-
sary.
Regularly check the hoses and hose connections for possible
leaks and fit new hoses and/or hose clips when necessary.
Also check the tank for damage caused by abrasion. Replace a
damaged tank immediately.
At the end of the cruising season, carry out the cleaning and
sterilizing procedures as described under "Use".
A tank and installation which is seriously polluted with algae
can be cleaned by thoroughly rinsing out the tank, pump and
pipes with chlorine
Technical Data
Type
Capacity
Dimensions
Height, full
Weight
Max. Pressure
Material
Hose Fittings:
For filler hose
For suction hose
For air-relief
*) Nominal capacity and weight values are stated here. Slight deviations may occur.
8
110106.04
:
TANKV55
:
55
12.1
14.5
:
68 x 78
27 x 31
:
25
10
:
1.8
4
:
24 kPa
(0.24 bar, 3.5 psi)
(0.24 bar, 3.5 psi)
:
Woven Polyester coated both sides with 'Alcryn'.
:
16 mm, 25 mm, 35 mm and 38 mm dia.
∕
", 1", 1
∕
" and 1
5
3
8
8
:
38 mm (1
1
:
16 mm (
∕
5
8
TANKV70
TANKV100
70
100
15.4
22
18.5
26.4
78 x 78
79 x 100
31 x 31
31 x 39
27
27
11
11
2.0
2.5
4.4
5.5
24 kPa
24 kPa
(0.24 bar, 3.5 psi)
∕
" dia.
1
2
∕
") dia.
2
") dia.
Flexible Waste Water Tanks for grey water and black water
TANKV160
160
35.2
42.3
79 x 142
31 x 56
27
11
3.3
7.3
16 kPa
(0.16 bar, 2.3 psi)
25 mm, 35 mm and 38 mm dia.
1", 1
∕
" and 1
∕
" dia.
3
1
8
2
38 mm (1
∕
") dia.
1
2
16 mm (
∕
") dia.
5
8
litres *)
Imp. gal. *)
US gal. *)
cms
inches
cms
inches
kgs *)
lbs *)