Supplement
Process conditions
Process pressure
Process temperature
Density
Electromechanical data
Cable entry/plug (dependent
on the version)
Spring-loaded terminals
Adjustment elements
Mode switch
Min.
-
Max.
-
Voltage supply
Supply voltage
Power consumption
Electrical protective measures
Protection
Overvoltage category
Protection class
Approvals
ATEX II 1/3 D IP66 T (optional)
20
-1 ... 25 bar/-100 ... 2500 kPa
-50 ... +150 °C
> 0.1 g/cm³
1 x cable entry M20 x 1.5 (cable: ø 5 ... 9 mm), 1 x blind stopper
M20 x 1.5; attached 1 x cable entry M20 x 1.5
for wire cross-section up to 1.5 mm² (AWG 16)
Min. detection or dry run protection
Max. detection or overfill protection
20 ... 253 V AC, 50/60 Hz, 20 ... 72 V DC (at U > 60 V DC, the ambient
temperature can be max. 50 °C/122 °F)
1 ... 8 VA (AC), approx. 1.3 W (DC)
IP 66/IP 67
III
I
VEGAWAVE S 61