11. Connecting the Supply Adapter and Inlet Filter
A) Locate remaining length of white 1/4" plastic tubing .
B) Push into quick connect fitting on the right side of system.
C) Cut the tube to a length that will allow connection to the cold
water supply fitting. Ensure the tubing does not kink. Push the
tube into the fitting.
1/4" Tube
Figure 16
Port Reference
Back View
B
Figure 17
• 8 •
A
5/8"
5/8"
12. Installing the Membrane
A) Remove tube attached to membrane housing by pressing in the
white collar around the fitting while pulling the tubing with your
other hand .
B) Hold the membrane housing with one hand and turn the cap
(wrench provided) with other hand to remove . To make it easier
to hold the membrane housing, you may want to remove the
postfilter.
With clean hands (sanitary gloves preferred), remove the membrane
from the plastic bag . HANDLE WITH CARE .
CAUTION:
Do not unwrap the tape around the membrane, as it is part
of the membrane . Do not squeeze membrane .
C) Use clean silicone grease (pack is included with the system) to
lubricate both O-rings and the brine seal .
D) With the double O-ring side first, push membrane into housing
until it stops . About 1/8" of the membrane's plastic core will stick
out beyond the housing .
E) Hand-tighten membrane housing cap until you feel resistance,
then tighten an additional 1/2 turn . Do not over-tighten .
F) Reinsert the tube by pushing it into the quick connect fitting.
Figure 18
Port Reference
Back View
A
Figure 19
C
D
E

Publicidad