Pulsar HELION 2 XQ Serie Manual De Instrucciones página 10

Ocultar thumbs Ver también para HELION 2 XQ Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 30
Exit the rangefinder mode with a long press of the М (9) button or wait 10 seconds to exit automatically.
DISPLAY OFF FUNCTION
This function deactivates the transmission of an image to the display by minimizing its
brightness. This prevents accidental disclosure. The device keeps running.
When the device is on, press and hold the ON (11) button.
The display goes out and the message Display Off appears.
Turn the display back on with a short press of the ON (11) button.
When you press and hold the ON (11) button, the display shows the message
Display Off with a countdown. Pressing & holding the button down for the
duration of the countdown will power the device off completely.
PIP FUNCTION
PiP (Picture in Picture) allows you to see a zoomed image simultaneously with
the main image in a dedicated window.
Turn on/off the PiP function with a long press of the DOWN (8) button.
Change the zoom ratio in the PiP window with a short press of the DOWN (8) button.
The zoomed image is displayed in a dedicated window with the full optical magnification being shown.
The main image is shown with optical magnification ratio which corresponds to x1.0.
When PiP is turned on, you can operate the discrete and smooth digital zoom. The full optical magnification
will take place only in the dedicated window.
When PiP is turned off, the image is shown with the optical magnification set for the PiP function.
STREAM VISION
Helion 2 thermal imagers support Stream Vision technology which allows you to stream an image from the
thermal imager to a smartphone or tablet in real time via Wi-Fi.
Detailed instructions on the operation of Stream Vision technology can be found in a separate booklet or on
the www.pulsar-vision.com website.
Note: the Stream Vision application allows you to update the firmware features of your Pulsar Device.
How to update instructions are as below:
Download free of charge Stream Vision App on
Stream Vision free of charge:
Connect your Pulsar device to your mobile device (smartphone or tablet).
Launch Stream Vision and go to section My Devices.
Select your Pulsar device and press Check Updates.
Important:
if your Pulsar device is connected to phone, please turn on mobile data transfer (GPRS/3G/4G) to download
update;
if your Pulsar device is not connected to your phone but it's already in the My Devices section, you may use
Wi-Fi to download update.
THERMAL IMAGING SCOPE HELION 2 XQ
Google Play
or
App
Store. Scan the QR codes to download
Wait for the update to download and install. Pulsar device will reboot and will
be ready to operate.
USB CONNECTION
Connect one end of the USB cable to the Micro-USB (4) port of your device and
the other end to the USB port of your PC / laptop.
Turn the device on with a short press of the ON (11) button (a device that has been turned off cannot be
detected by your computer).
Your device will be detected by the computer automatically; no drivers need to be installed.
Two connection modes will appear on the display: USB Mass storage device (external storage device) and
Power
Select the connection mode with the UP (10) and DOWN (8) buttons.
Confirm the selection with a short press of the M (9) button.
CONNECTION MODES:
USB Mass storage device. In this mode the device is detected by the computer as a flash card. This mode is
designed for work with the files saved in the device's memory. The device's functions are not available in this
mode; the device turns off automatically.
If video recording was in progress when the connection was made, recording stops and the video is saved.
When the USB is disconnected from the device where connection is in the USB Mass storage device mode, the
device remains in the Off state. Turn the device On for further operation.
POWER
In this mode, a PC/laptop is used as an external power supply. The status bar shows the icon
device continues operating and all functions are available.
The Battery Pack installed in the device is NOT being charged.
When the USB is disconnected from the device when in the Power mode, the device keeps operating with the
Battery Pack if it is available and sufficiently charged.
MAINTENANCE AND STORAGE
Maintenance should be carried out at least twice a year, and should consist of the following measures:
Wipe external plastic and metal surfaces with a cotton cloth to remove dust and dirt. Silicone grease is
allowed.
Clean the electric terminals of the Battery Pack and the device's battery slot using a grease-free organic
solvent.
Check the objective and eyepiece lenses. If required, remove dust and sand (preferably by a noncontact
method). Clean the external surfaces of the lenses with products expressly designed for this purpose.
Store the device in a carrying case. Remove the Battery Pack for long-term storage.
TECHNICAL INSPECTION
Maintenance should be carried out at least twice a year, and should consist of the following measures:
Wipe external plastic and metal surfaces with a cotton cloth to remove dust and dirt. Silicone grease is
allowed.
Clean the electric terminals of the Battery Pack and the device's battery slot using a grease-free organic
solvent.
Check the objective and eyepiece lenses. If required, remove dust and sand (preferably by a noncontact
method). Clean the external surfaces of the lenses with products expressly designed for this purpose.
. The
10

Publicidad

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

Helion 2 xq50fHelion 2 xq38f7739777396

Tabla de contenido