• Press the arbor lock button to lock the arbor. (Fig. 4)
• Unscrew the arbor bolt using the wrench.
Note: The arbor bolt has a right hand thread.
• Remove the saw blade, leaving the inner blade flange in its
service position.
• Thoroughly clean inner and outer blade drive flanges and
blade mounting surface before installing a new blade.
• Ensure that the direction of rotation arrows printed on the
blade match the direction of rotation arrow found on the
chip collector. (Fig. 5)
• Reinstall the outer drive flange and the arbor bolt.
• Engage the arbor lock and tighten the arbor bolt securely
using the wrench.
• Replace the chip collector and securely tighten the thumb screw.
• Check that the arbor lock is fully released by manually
rotating the blade.
• Replace the wrench and secure it into the base plate using
the thumb screw.
• Replace the parallel edge guide if required.
Parallel Edge Guide
A parallel guide (for help when rip cutting) can be fitted to the
base plate of the machine. The guide's arms should be inserted
into the rectangular slots in the turned up edges of the base
plate, and slid under the locking thumb screws. (Fig. 6)
Note: The parallel edge guide can be fitted to either side of
the base plate and should only be fitted and adjusted with the
machine disconnected from the power supply.
Adjust the parallel edge guide so that it is at the required
distance from the blade and tighten the two thumb screws.
Check that the parallel edge guide is parallel to the saw blade.