Operation
Arrangement and Function of the Controls
5
Operation
DANGER
CAUTION
5.1
Arrangement and Function of the Controls
Figure 6
1
Main switch (SGR only)
2
Emergency Stop button
3
Potentiometer
Position
number
1
2
3
4
5
4330053_A7
Defective emergency stop
In case of fault, e.g. from defective fuses, the drives may continue to run even
after the emergency stop has been pressed.
Rotating machine parts
Avoid any direct contact with the running conveyor belt and the outlet, feeding
and deflection points during operation or when performing any other work.
There is an indirect risk of injuries of the fingers caused by being pulled into
the appliance and crushing.
Never reach into the hazardous area of the conveyor system during operation.
Before switching on the conveyor system, make sure there is no risk of
reactivation of the belt.
Controls
Control
Main switch (SGR only)
Emergency Stop button
Potentiometer
Stop button
Start button
4
Stop button
5
Start button
Function
Switches the conveyor system on.
Is used to switch off the appliance quickly in case of
emergency. If you have pressed the Emergency
Stop button, the power supply of the drives of the
whole conveyor system will be interrupted.
Controls the speed of the belt:
V min. = 13 ft/min. (4 m/min.)
V max. = 66 ft/min. (20 m/min.)
Stops the conveyor system if needed.
Starts the conveyor system.
Section 5
Page 27
Belt Conveyor System
SGR | SPV