GE Side by Side 22 Manual Del Propietario E Instalación página 34

Ocultar thumbs Ver también para Side by Side 22:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Performance Data Sheet
SmartWater
Filtration System-GE ®HSWF Cartridge
This system has been tested and certified
in filter mode} GE HSWF according
to NSF/ANSI Standards
42 and 53 for reduction
of the substances
}isted be}ow.
The concentration
of the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissib}e limit for water
leaving the system, as specified
in NSF/ANSI Standards
42 and 53.* (Safety factors built in for unmetered
usage.)
Standard
No. 42: Aesthetic
effects
'
!nfluent Cha!lenge
Effluent
O/o Red,uction
I
Parameter
'
USEPAHCL
Concentration
Average
Maximum
Average
Maximum
Min. Required Reduction
; ::l:::
Ta
: _
-
2.0rag/L±10%
0.06mg/L
0.10mg/L
97%
9.1%
-
at least 10,0O0partic}es/
408,333
670,000
95.5%
89.4%
mL
Standard
No. 53: Health
effects
,
Influent Challenge
'
Effluent
....
% Reduction
Parameter
'
USEPAMCL
Concentration
!i_i_!_i_ii_
_l_l_!_i!il!l_liiliiil!llll_l_l_l_ill_l_ililliiill_i_!ill_l_l_l_l_l_l_l_l_l_l_l_l_l_l_l_l_l_l_l_l_i!_i!_i!i!_!_lll_li_
i!_1_!_lii_i!!i_ii!!ii_!!i_i_i!%!_i!_i!!_i_i_i_i_i_i_i_i_i_i_i_iii_iii_:i:iii!_!_i!i!iii!_ii;;
ii_i_l_illlllllllliiiiiii_ii_i!!i!i!i!i!i!_i_iiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_i_!llllllli
¸
iiiiiiiiiiiiiiiiiiiiiiiiiiiiiii_i_i!_i,ii!i!i!i!i!iiiiii!iiiiiiiiiiii!iiiiii
_I_I_I_I_I_I_I_I_I_I_I_I_I!II
_!!!_i!!_!_!_!_l!!_!_i_i!i!i!i!i!i!i!i!i!i!i!ii
_
Average
Maximum
1 NTU....
ii ± 1 NTU....
0.38 NTU
0.5 NTU
99.95% Reduction
Minimum 50,000 L
< 1 #/L
4 #/L
0.010 mg/L
0.15 rag/L_+10%
< i ppb
< i ppb
0.010 mg/l_
0.15 mg/l_ ± 10%
5.1 ppb
9.0 ppb
0.002 mg/L
0.006 mg/L ± 10%
0.34 ppb
0.7 ppb
0,002 mg/L
0,006 mg/L± 10%
0.66 ppb
1,5 ppb
0.0002 mg/L
0.002 mg/L ± 10%
<0.02 ppb
<0.02 ppb
0.003 mg/L
0.009 mg/L ± 10%
< 0.5 ppb
< 0.05 ppb
0.070 mg/L
0.210 mg/L _+ 10%
7.7 ppb
35 ppb
0.003 mg/L
0.015 mg/L± 10%
< 1 ppb
< 1 ppb
0.005 mg/L
0.015 mg/L ± 10%
< 0.5 ppb
< 0.5 ppb
0.040 mg/L
0.080 mg/L ± 10%
< i ppb
I ppb
0.075 mg/L
0.225 mg/L _+ 10%
<0.5 ppb
< 0.5 ppb
99% Reduction
107 to 10 8 fibers/L;
<0.17 MF/L
< 0.17 MF/L
fibers > lOpm in length
*Tested using pressure of 60 psig; pH of 7.5_+0.5; temp of 68°_+5% {20 ° _+2.5°C).
**Measurement
in Portides/mL
Particles used were 0.5-1 microns.
***Based on the use of Cryptosporidium
porvum oocysts
....
NTU=Nephelometric
Turbidity Units
Capacity 300 gallons (1.13S liters}. Contaminant
reduction
determined
by NSFtesting.
Average
96.5%
> 99.99%
99.3%
98.0%
94.0%
88.4%
> 99.0%
>93.9%
96.0%
>92.9%
> 96.8%
>98.7%
> 99.7%
>99%
Maximum
95.4%
> 99.99%
99.3%
95.5%
89.6%
73.7%
>99.0%
>94.3%
82.0%
>92.9%
> 97.0%
> 98.7%
> 99.8%
> 99%
m 50%
m85%
: Max, Permissibl e
Product Water
0.5 NTU
99.95%
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.0002 mg/L
0.003 mg/L
0.070 mg/L
0.003 mg/L
0.005 mg/L
0.040 mg/L
0.075 mg/L
99% Reduction
Application
Guidelines/Water
Supply
Parameters
Service Flow
Water Pressure
Water SU_
Water Temperature
It is essential that the manufactureCs recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
Seeinsert for Warranty information.
Operating
Specifications
, Pressure requirement:
40-120 psi (2.8-8.2 bar), non-shock
. Temperature: 33-100°F (0.6-38°C)
• Flow rate: 0.9 gpm (3.14 }pm)
General
Installation/Operation/Maintenance
Requirements
• Flush new cartridge at full flow for 4-1/2 gal}ons (about five minutes) to purge
trapped air.
• Pep}ace cartridge when flow becomes too slow.
, Protect from freezing by removing
filter cartridge when temperatures
are
expected to drop below 40°F (&4°C). Do not install systems in areas where
ambient temperatures
may go above 100% or below 40°R Do not insta}l
on a hot water supp}y.
Special
Notices
° Installation instructions
are included with the product when shipped.
° This drinking water system must be maintained
according to manufacturer's
instructions, including replacement of fi}ter cartridges.
• Do not use with water that is microbio}ogically
unsafe or of unknown quality with-
out adequate disinfection before or after the system. Systems certified for cyst
reduction may be used on disinfected
water that may contain filterab}e cysts.
, The contaminants
or other substances removed or reduced by this water
treatment
system are not necessarily in your water.
• Check for compliance with the app}icab}e state and local lows and regulations.
• Note that while the testing was performed under standard }aboratory conditions,
actual performance
may vary. Systems must be installed and operated in
accordance with manufacturer's
recommended
procedures and guidelines.
• Installation
and use MUST comply with all state and local p}umbing codes. Do not
install if water pressure exceeds 120 psi. If your water pressure exceeds 80 psi
(552 kPo),you should insto}l o pressure-limiting
valve. Contact a plumbing
professional if you ore uncertain
how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install o water hammer arrester. Contact o plumbing
professional if you ore uncertain
how to check for this condition.
• Where a backflow prevention device is installed on a water system, a device for
controlling pressure due to thermal expansion must be installed.
For conditions of use, health claims certified by the California Deportment
of Public
Health, and rep}acements,
see performance
data sheet. California Deportment
of Public Health Certification
#06-183/4. The contaminants
or other substances
removed or reduced by this water filter are not necessarily in all users' water.
Tested and Certified
by NSF International
against
ANSI/NSF Standards
42 and 53 in model
GE MSWF for the reduction
of:
Standard
No. 42: Aesthetic
Effects
• Chemical
- Chlorine Taste and Odor
,
Mechanical Filtration
- Particulate
Reduction.
Class I
GE
Appliances
Appliance Park
Louisville, KY40225
geapplianceparts.com
Standard
No. 53: Health
Effects
• Chemical
Reduction
- Atrozine
Reduction
- Endrin Reduction
- Benzene and Cmrbofuran
Reduction
- 1,4 Dichtorobenzene
and
2,4-D Reduction
- Lead and Lindone Reduction
- Mercury and Toxaphene Reduction
• Mechanical Filtration
- Cyst and Asbestos Reduction_
REPLACEMENT
ELEMENT
EPA #10350-MN-005
© 2010 General Electric Company
PC61577C
34

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido