CONFORMITY DECLARATION

The Manufacturer declares that the appliances conform to EEC directive 90/396 regarding gas system parts and directive
73/23 regarding electrical system parts. The installation must be carried out in observance of the standards in force above
all regarding the airing of the rooms and the evacuation system of the exhaust gases.
N.B. The manufacturer declines all responsibility for direct or indirect damage caused by incorrect installation, alterations,
poor maintenance, incorrect use and all the other cases provided for in the articles stated in our sales conditions

INSTALLATION

Technical specifications table "GAS"
MODEL
DIMENSIONS
cm.
PC - 4G
40x65x29h
80x65x29h
PC -8G
120x65x29h
PC - 12G

INSTALLATION OF THE APPLIANCE

Installation, any transformations for other types of gas and starting can be done only by qualified personnel according
to the standards in force.
The gas systems, electrical connections and the rooms where the appliances are installed must be in accordance with
the standards in force in the country where they are installed; particularly, the appliance must be installed in a well
aired room, possibly under a suction hood to guarantee complete evacuation of the exhaust gases that are formed
during combustion; the necessary air for combustion is 2 m

CHECKING FOR ADEQUATE VENTILATION

Make sure that the air intake into the room where the appliance is installed is sufficient for an adequate change of air, as
specified by regulations in effect.
The appliances installed in buildings open to the public must satisfy the following requirements.

1) Installation rules

The installation and maintenance of the appliance must be done according to the correct procedures and regulation
texts in use, particularly:
safety standards for the prevention of fire and panic.
Connection and installation of appliance, ventilation and exhaust removal systems, shall be done according to the
Manufacturer' s instructions and by qualified technicians and according to the regulations in effect. The electric wiring shall
conform to the regulations in effect. All fire prevention codes shall be observed.
a)
General indications (Rules valid for G.B. only)
-
For all appliances:
Gas safety Regulations, 1984; Health and safety at Work Act, 1974 Codes of Practice, BS 8173, 1982, The Building
Regulations 1985; The Building Standards Regulations, 1981, the IEE Regulations and the by-laws of the local Water
Undertaking.
The local gas Region or LPG supplier and the local authority and the relevant recommendation of the British Standards
(latest editions) concerned.
GB
IE
NOMINAL CAPACITY kW
Burner
3,5 kW
1
2
3
3
24
TOTAL
NOMINAL
Burner
CAPACITY kW
5,5 kW
1
9
2
18
3
27
/h per kW of installed power.
GAS
CONN. ISO R7
R 1/2"
R 1/2"
R 1/2"