Mi-T-M CWC-GASOLINE Manual Del Usuario página 18

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

a. Two 5 gallon containers.
b. One gallon of antifreeze. (Mi-T-M recommends an environmentally safe
antifreeze.)
c. Water supply.
d. Three foot hose, 1/2-3/4 I.D. with a 3/4 inch male garden hose fitting.
WARNING: RISK OF UNIT BURSTING. DO NOT STORE / OPERATE UNIT
IN A FREEZING ENVIRONMENT!
2. Procedure:
a. Shut off the unit and water supply.
b. Relieve system pressure by pointing the trigger gun in a safe direction and squeezing the trigger until
water flow ceases to exit the nozzle.
c. Lock the trigger gun in an OFF position and remove the nozzle.
d. In one 5 gallon container, mix the antifreeze and water according to manufacturer's recommendations
for the temperature to which you are winterizing.
NOTE: Proper winterizing is based on the recommended manufacturer's instructions listed on the "Protection Chart" shown on
the back label of most antifreeze containers.
e. Remove the water supply hose from the unit and attach the 3 foot hose securely to the inlet connection.
Submerge the opposite end into the antifreeze solution.
f. Point the lance into the empty container and start the unit.
g. Trigger the gun until the antifreeze begins to exit the lance. Release the trigger for 3 seconds; then,
trigger the gun for 3 seconds. Continue cycling the gun several times until all the antifreeze mixture is
siphoned from the container.
h. Detach the 3 foot hose from the unit and drain any excess antifreeze back into a 5 gallon container.
i. Disconnect the hose/gun/lance assembly from the unit and drain any excess antifreeze back into a 5
gallon container.
j. Store the hose, gun and lance with the unit in a safe area.
k. Store antifreeze solution for next use or dispose of according to state EPA laws.
3. Optional procedure:
a. Shut off the unit and water supply.
b. Relieve system pressure by pointing the trigger gun in a safe direction and squeezing the trigger until
water flow ceases to exit the nozzle.
c. Disconnect and drain the hose, gun and lance.
d. Start the unit and allow it to run until all the water exits the unit. Once the water has stopped flowing
from the unit, turn the unit off.
NOTE: When using this procedure, caution should be used as ice chips can form from drops of water which could cause the
unit to burst if starting before completely thawed.
18
STORAGE & MAINTENANCE
32˚F
0˚C
CWC-GASOLINE Operator's Manual