Truper SME-10 Instructivo página 25

Sierra de mesa
Ocultar thumbs Ver también para SME-10:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Adjustments
Calibrate the Disc Angle with Regards to the Work Table Surface
• Lift the disc completely and adjust the cutting angle to 0°(see page 8).
• Place a square set against the table surface and against the disc face.
• In the event the disc face in not making contact completely with the square set
profile, calibrate the angle loosening the screw (H).
• With the loose screw, adjust again the cutting angle to 0° as indicated in page 8.
• After tightening the cutting angle blocking knob, tighten the screw until feeling
resistance, not more.
• Check the scale and the cutting angle pointer to assure it signals the 0.
Otherwise, loosen the pointer angle and move it until it shows the 0 and tighten
the screw again.
Calibrate the Disc Angle with Regards to the Miter Guide Slots
• Lift the disc completely and adjust the cutting angle to 0°
(see page 8).
1. Select one of the disc teeth that point to the left and
mark it with a pencil or marker.
2. Turn the disc manually until the marked tooth is pointing
to the saw front and is barely over the work table surface.
• Set a set square onto the work table, supporting one of its
profiles in the miter guide face adjusted to 90° and move it
until touching the marked tooth.
• Using care not to move the set square, push the miter
guide to the center of the disc.
• Turn the disc manually up to the mark tooth points the
rear side of the saw and is barely over the work table
surface.
3. Push the miter guide again until the tip of the square set
touches the marked tooth.
• In the event, it is not touching the tooth or the disc moves
the square set out of its place in the miter guide, the disc
must be calibrated.
4. To calibrate the disc, remove the miter guide and loosen
the four screws ( I ). Hold the disc and adjust it to be
parallel to the miter guide slots.
• Repeat the previous steps to verify the angle until it is
parallel to the slots.
• Only in the event the angle cannot be
CAUTION
corrected after loosening the 4 screws ( I ), loosen the two
screws (K) to make the adjustment.
• Once the angle is calibrated, tighten all the screws.
1
2
3
I
4
K
ENGLISH
H
9

Publicidad

Capítulos

Tabla de contenido

Solución de problemas

loading

Este manual también es adecuado para:

16143

Tabla de contenido