P1 P2 P3
P4 P5 P6
P15 P14 P16
ST1
FT1
ST2
FT2
FCA1
FCC1
The VULCAN S operator has a safety device (cable connectors 5 and 6), making it necessary to use the
VIVO-M101(M) switchboard. In order for this device to work properly, first connect cable connectors 5 and
6 of the operator to the FCA cable connectors of the VIVO-M101(M) switchboard and place DIP12 in ON.
The VIVO-M101(M) or VIVO-M201(M) switchboard can be used for the VULCAN operator without internal
safety device.
The opening and closing pressures must be adjusted to fulfil standard EN12453:2000.
Clockwork turning increases the pressure for both screws. Anti-clockwork turning reduces the pressure.
O
Do not tighten the regulation screws (2) and (3) to the maximum, as this will result in damage.
CLOSING PRESSURE: yellow colour cap, screw (2).
The "Closing Pressure" is, more exactly, the pressure
during the extension of the spindle. In inward opening
facilities, it corresponds to the closing operation. In
outward opening facilities, it corresponds to the opening
operation.
12
VULCAN
G1
G2
G3
P7 P8
P11 P12
P22 P23
G7 G8
G9 G10
Courtesy
24Vac
Lamp.
MOTOR1 (G2-G1-COM)
STOP
LOCK
Light
VIVO- M101:
230Vac/ 50Hz
VIVO- M101M:
125Vac/ 60Hz
Adjusting the opening and closing pressures
Electrical connections
VIVO-M101(M)
P1 P2 P3
N
L
POWER
ST1
FT1
N L
P140W
OPENING PRESSURE: white colour cap, screw (3).
The "Opening Pressure" is, more exactly, the pressure
during the retraction of the spindle. In inward opening
facilities, it corresponds to the opening operation. In
outward opening facilities, it corresponds to the closing
operation.
VULCAN S
P4 P5 P6
P15 P14 P16
P7 P8
P11 P12
P22 P23
G7 G8
G9 G10
Courtesy
24Vac
Lamp.
ST2
FT2
FCA1
FCC1
STOP
LOCK
Light
G1
G2
G3
N
L
POWER
MOTOR1 (G2-G1-COM)
N L
VIVO- M101:
230Vac/ 50Hz
VIVO- M101M:
125Vac/ 60Hz
P140W1