Testing diode

Plug the black test lead into the
COM jack and the red test lead into
the INPUT jack.
Set the rotary selector to the
range position.
Press the "SEL" button to switch to
test.
Connect test leads to the two end of
the source or load for measurement.
Take the reading on the LCD.
NOTE:
1.
The meter will show the
approximate forward voltage
drop of the diode.
2.
When the test leads have been
reversed or open, 'O L'will
appear on the LCD.
Instructions manual |
44

Testing Continuity

WARNING
Beware of Electrocution.
Make sure that the power of the
circuit has been turned off and
the capacitors have been fully
discharged before testing the
continuity of a circuit.
Plug the black test lead into the
COM jack and the red test lead into
the INPUT jack.
Set the rotary selector to the
range position.
Press the "SEL" button to switch to
continuity test.
Connect test leads to the two end of
the source or load for measurement.
If the resistance of the circuit being
tested is less than 40Ω, the built-in
buzzer will maybe sound.
Take the reading on the LCD.
NOTE:
If the test leads are open or the
resistance of the circuit is over 400Ω ,
"O L" will appear on the LCD.