Caution!
The wall-mounting plate must be attached, as otherwise the outlet cannot be fixed
with the necessary stability.
If an installation frame is used, it should be ensured that the wall-mounting plate can
be attached.
10.1 Create a wall recess. Choose the depth of the wall recess so that the front edge of the
wall mounting box (d) is flush with the front edge of the masonry (in front of the tiles).
10.2 Remove the transport protection of the wall-mounting plate (a).
10.3 Separate the pipe (b) from the flush connector (c).
10.4 Place the wall mounting box (d) against the wall and mark the holes for the wall
mounting plate (a) and the wall mounting box (d).
10.5 Drill holes in accordance with these markings.
Insert the wall plugs.
10.6 Insert the wall mounting box (d) horizontally into the wall recess provided and screw
it in place.
10.7 Fasten the wall mounting plate (a).
10.8 Attach the pipe (b) to the flush connector.
Caution!
Use an open-ended wrench to hold the water quantity regulators (f) in position while
turning the cap nuts (e).
10.9 Establish the water connections.
10.10 Align the water volume regulators (f) so that the locking screw (g) and operating
element (h) are freely accessible. Loosen the flush connector for this purpose, if
required.
10.11 Install the system cable (i) in the empty pipe and pull it from fitting to fitting.
Allow approximately 50 cm of system cable to hang out of the wall mounted box.
10.12 Connect the electrical T-distributor (k).
Install the electrical T-distributor
Important!
The components of the electrical T-distributor may only be installed after the power
has been switched off.
Recommended system cable (see
When using cables other than the system cable, pay attention to the different colour
code. The outer diameter must not exceed 7.5 mm.
10.13 Remove the sheathing (l) of the system cable (approx. 40 mm).
10.14 Push the cap nut (n) onto the system cable (m) up to the limit stop.
Chapter