21. Replace the thermal element
Warning!
Set the scald protection after installing the fitting or removing the thermal element.
Failure to observe this instruction can result in injuries due to scalding.
21.1 Remove the cover plate (see
21.2 Remove the screw (b)
Caution!
Apply the pliers to the area with the largest diameter (a) behind the small sprocket
wheel.
If the sprocket wheel is damaged, the temperature selector cannot be installed.
21.3 Use pliers to remove the thermal element (c).
☞
Important!
Note the installation position of the thermal element.
21.4 Reassemble in reverse order.
21.5 Set the scald protection (see
22. Replacing the flow rate regulator
22.1 Remove the cover plate (see
22.2 Undo the grub screw (a), using an Allen key.
22.3 Remove the wall bracket (b) from the connection piece.
22.4 Remove the locking ring on the inside using appropriate pliers for locking rings.
22.5 Pull out the flow rate regulator using flat-nosed pliers.
☞
Important!
Note the installation position of the flow rate regulator. The struts must point towards
the shower head.
22.6 Insert the flow rate regulator and secure with the locking ring.
c: Struts
d: Direction of flow
22.7 Slide the wall bracket (b) onto the connection piece.
22.8 Undo the grub screw (a), using an Allen key.
22.9 Reassemble in reverse order.