Kollmorgen
Mechanical Installation
15
Dimension drawings can be found in chapter "Dimension Drawings" from p. 79.
15.1
Important Notes
Only qualified staff with knowledge of mechanical engineering are permitted to assemble
the motor.
Always make sure that the motors are de-energized during assembly and
wiring, i.e. no voltage may be switched on for any piece of equipment
which is to be connected.
There is a risk of death or severe injury from touching exposed contacts.
Ensure that the switch cabinet remains turned off (barrier, warning signs
etc.). The individual voltages will only be turned on again during setup.
The mounting end of the motor is magnetized and will attract magnetic material. If the
motor is not mounted, this end of the motor must be covered to insure proper cleanliness.
l
Protect the motor from unacceptable stresses.
Take care, especially during transport and handling, that components are not bent
and that insulation clearances are not altered.
l
The site must be free of conductive and aggressive material. If an encapsulated as-
sembly is required, please consult our applications department beforehand.
l
Assemble the motor according to the instructions on page 34
When assembling, ensure that the fastening of the motor is not mechanically over-
determined.
l
Ensure an unhindered ventilation of the motors and observe the permissible ambient
and flange temperatures. For ambient temperatures above 40°C please consult our
applications department beforehand.
Servomotors Cartridge DDR
04/2017
DANGER
Mechanical Installation
English - 33