Drufomat scan
9.3 Calling of individual time programmes
Turn on the unit – the initial display
will be visible. By pushing the menu
key (j) several times you may select one
after another
a) enter modus
b) F1
c) F2
d) F3
By pressing the menu keys (d/j) you may
navigate arbitrarily between the a. m.
programme points. Confirm the selected
programme point with the OK key (f).

9.4 Plasticizing of blanks with unknown heating times

Create an individual time programme
with high heating and cooling times
(see point 9.2). Start the programme
(see point 8.2). You may test the plas-
ticization degree of the blank by means
of an edgeless metal instrument (e. g.
wax knife).
Info
The complete deformability of the
blank can only be tested at the
edges, as that is where warmth

9.5 Abort/termination of programme

It is possible to abort / terminate all
actions of the Drufomat scan by push-
ing the push button (8) at the left side
42
Then go on as described in point 8.2.
will leak through the metal con-
tacts and the necessary flexibility
will be attained at last!
After the blank has attained the neces-
sary flexibility initiate the thermoforming
process (see point 8.4). The remaining
heating time will be erased from the dis-
play (a) and the adjusted cooling time
will be counted down (c). The cooling
time can be terminated at any time by
pushing the push button (8).
of the unit (keep pushed for aprox.
2 seconds!).
9.6 Exceeding of entered heating/cooling times
After elapse of times adjusted regu-
will be blinking in the display as control
larly (display position a/c) there will be
mechanism.
an acoustic signal. The exceeded time
9.7 Entering a wrong barcode
If a barcode is scanned that does not
By scanning the correct barcode you
correspond to the programming of the
can proceed further, as described in
Drufomat scan, four acoustic warning
point 8.0.
signals will be heard and the display will
show ERROR at position b.