TROUBLESHOOTING
If the possible causes listed below are not the source of trouble, it is a symptom of something more serious. Contact your Nilfi sk-Advance
Service Center immediately for service.
MACHINE WILL NOT MOVE
Possible causes may be:
1
Parking Brake (GG) set (release parking brake)
2
Towing Valve in wrong position (set correctly)
3
Tripped circuit breaker(s) (reset any tripped circuit breakers)
MAIN BROOM WILL NOT RUN
Possible causes may be:
1
Debris wrapped around the broom drive (remove debris)
2
Hopper is not completely down (lower hopper completely)
3
Tripped circuit breaker(s) (reset any tripped circuit breakers)
SIDE BROOMS WILL NOT RUN
Possible causes may be:
1
Debris wrapped around the broom drive (remove debris)
2
Hopper is not completely down (lower hopper completely)
3
Tripped circuit breaker(s) (reset any tripped circuit breakers)
HOPPER WILL NOT RAISE
Possible causes may be:
1
Tripped circuit breaker(s) (reset any tripped circuit breakers)
HOPPER DUMP DOOR WILL NOT OPEN
Possible causes may be:
1
Dump door jammed by debris (remove debris and clean edges of dirt chamber)
2
Tripped circuit breaker(s) (reset any tripped circuit breakers)
SHAKER MOTOR WILL NOT RUN
Possible causes may be:
1
Tripped circuit breaker(s) (reset any tripped circuit breakers)
DUST CONTROL SYSTEM (IMPELLER) WILL NOT RUN
Possible causes may be:
1
Tripped circuit breaker(s) (reset any tripped circuit breakers)
SCRUB SYSTEM WILL NOT RUN
Possible causes may be:
1
Tripped circuit breaker(s) (reset any tripped circuit breakers)
2
Hopper is not completely down (lower hopper completely)
NO DETERGENT FLOW (AXP/EDS)
Possible causes may be:
1
Tripped circuit breaker(s) (reset any tripped circuit breakers)
2
Empty detergent cartidge (fi ll detergent cartidge)
3
Plugged or kinked detergent fl ow line (Purge system, straighten lines to remove any kinks)
4
Dry seal cap on detergent cartidge not sealed (reseat dry seal cap)
5
Detergent ratio slider magnet missing (replace slider)
6
Detergent pump wiring disconnected or backwards (connect or reconnect wiring)
revised 11/07
FORM NO. 56041580 - Captor
ENGLISH / A-29
4300, 4800, 5400 / CR 1100, 1200, 1400 - A-29
™