EdilKamin MIMI’ Instalación Uso Y Mantenimiento página 28

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 59
HYDRAULIC CONNECTIONS
System with production of stored hot sanitary water with Idrokit combined with boiler.
This diagram is purely indicative. The plumber is responsible for a correct installation.
System set-up as sole source of heat with boiler to produce hot sanitary water.
This diagram is purely indicative. The plumber is responsible for a correct installation.
ATTENTION: the power to the radiators decreases when Hot Sanitary Water is produced.
ACCESSORIES
Edilkamin accessories have been used in the above diagrams.
• IDROKIT for the production and storage of hot sanitary water (code 601750)
• 200-litre boiler (code 633230) or 300-litre boiler (code 633240) to produce and store hot sanitary water.
Individual spare parts are also available (exchanger, valves, etc). For information, please contact your local dealer.
KEY
ACS: Hot sanitary water
AF:
AL:
C:
CE:
EV:
NA:
NC:
GR:
Ja:
Jm:
MI:
MT:
P:
RA:
RI:
S:
SC30: 30-plate exchanger
ST:
TC:
TS:
V:
Vec:
VR:
VSPT: Safety Pressure and Temperature Valve
KEY
ACS: Hot sanitary water
AL:
B:
C:
EV2: 2-way solenoid valve
EV3: 3-way solenoid valve
NA:
NC:
GR:
MI:
P:
RA:
RI:
S:
TS:
V:
Vec:
VSP: Safety valve
28
Cold water
Water mains supply
Filling/Top-up Section
Electronic panel
3-way solenoid valve
Normally open
Normally closed
Pressure reducer
Automatic relief valve
Manual relief valve
System flow
Thermostatic mixer
Pump (circulator)
Radiators
System return
Drain
Temperature sensor
Contact thermostat
Thermal stove
Ball valve
Closed expansion tank
Check valve
Water mains supply
Boiler
Filling/Top-up Section
Normally open
Normally closed
Pressure reducer
System flow
Pump (circulator)
Radiators
System return
Drain
Thermal stove
Ball valve
Closed expansion tank

Publicidad