15. Troubleshooting
Malfunction
Power indicator (1) stays inactive
VITO® makes loud noises at
filtration
Power Indicator (1) flashes and/or
acoustic indicator is beeping
Power Indicator (1) and filtration in-
dicator (2) flashing (VITO® 80 beeps
additionally)
VITO® cannot be started
Line fuse / Ground fault circuit
interrupter (GFCI) blowout
Low filtration performance
Oil splashes at sides / on top
LEDs flash 10 sec. after plugging in
Should other issues appear, get in contact with the customer support or your local dealer!
Contact details on page 2 chapter Legal information.
Possible cause
•
Power cord (8) not plugged in
•
Power cord (8) / connector is
defective
•
Star handles (5) are too loose
•
Rotor scratches on the fryer
•
Rotor defective
Sensor switch defective
•
VITO® is tilted more than 15°
•
Strong vibrations
•
Electrical unit (6) defective
•
Net protection or other elec-
tronic components are blocking
•
Rotor defective
•
Circuit overloaded
•
Particle filter is full
•
Pump pipe is blocked
•
Motor is defective
•
Particle filter blocked
•
Too much space between filter
lid and pump filter unit (9)
•
Filter is inserted incorrectly
•
Push button (3) is defective
Remedial action
•
Plug in VITO®
•
Please contact service
•
Tighten star handles (5)
•
Alter position of VITO® in the
fryer
•
Please contact service
•
Please contact service
•
Check position of VITO®
•
Check position of VITO®
•
Please contact service
•
Change power outlet, elec.
circuit
•
Please contact service
•
Change power outlet, elec.
circuit
•
Change filter
•
Empty pump-filter unit (9)
•
Please contact service
•
Change filter / clean unit
•
Adjust filter sealing sheet
•
Insert filter correctly
•
Please contact service
Page 9