Descargar Imprimir esta página

Desoutter CVI II Manual De Inicio Rápido página 8

Ocultar thumbs Ver también para CVI II:

Publicidad

Idiomas disponibles

Idiomas disponibles

6159931440
Issue no: 01
Series: -
ST : module status
Number of disconnections between the module
and the controller
ST module status
The following table is common to both ranges:
ST = Module Status
0000
Module initialisation
0001
Network / Fieldbus initialisation
0002
Module is expecting the
communication process with PLC.
0003
PLC is in Stop mode or PLC
requests module to go in IDLE
mode
0004
PLC & Module communication is
correct.
0005
Network / Fieldbus fault
0007
Fatal Error
8 / 32
CVi3 range
Main user info codes are:
232
Fieldbus module
not recognized
not a Desoutter
one
234
Fieldbus module
mismatch
1- The Fieldbus
module plugged in
the CVI3 cannot
be run it is not an
authorized Desoutter
module.
2- Contact
your Desoutter
representative for
more information.
1-The Fieldbus
module declared
in configuration is
not the same that
the one present
in controller (e.g.
Profibus declared
but a Profinet
module in CVI3).
03/2012

Publicidad

loading

Este manual también es adecuado para:

Cvix iiCvi3