RS10
3 . 9 Stop b utton connection: Normally closed contact, opening the contact causes the gate to stop and suspends the automatic closing
time (when the button is not engaged, the STOP LED should be lit), if not used then jumper between COM and STOP:
Fig. 12
3 . 10 C onnecting th e aerial:
The 17 cm rod is supplied pre-wired, to increase the range connect the aerial, as shown in the figure:
Fig. 13
4 . D escription of th e L E D S in th e circuit
A b b rev iation C olour L E D status
Off
O P E N
Red
On
Off
A P C H
Red
On
Off
A P E D
Red
On
Off
ST O P
Green
On
Off
P H O T O
Green
On
Off
ST P A
Green
On
Off
F C A P
Green
On
Off
F C C H
Green
On
D L 1
Red
"Fast blink"
22
17 18 19 20 21 22 23
N ormally closed b utton
5
T erminal status
APRI input (terminal 16) not engaged
APRI input (terminal 16) engaged
APCH input (terminal 18) not engaged
APCH input (terminal 18) engaged
APED input (terminal 19) not engaged
APED input (terminal 19) engaged
STOP input (terminal 21) engaged
STOP input (terminal 21) not engaged, if not used then jumper between COM and STOP terminals
PHOTO input (terminal 22) engaged (photocell beam interrupted)
PHOTO input (terminal 22) not engaged, if not used then jumper between COM and PHOTO ter-
minals
STPA input (terminal 23) engaged (sensitive edge pressed)
STPA input (terminal 23) not engaged, if not used then jumper between COM and PHOTO termi-
nals
"FCAP input (terminal 13) engaged. The gate is in the position of:
Opening limit switch if parameter P18 = R (opening to right)
Closing limit switch if parameter P18 = L (opening to left)"
FCAP input (terminal 13) not engaged.
"FCCH input (terminal 15) engaged. The gate is in the position of:
Closing limit switch if parameter P18 = R (opening to right)
Opening limit switch if parameter P18 = L (opening to left)"
FCAP input (terminal 15) not engaged.
Flashes quickly if one of the inputs is engaged