RS10
P arameter tab le
P arameter numb er D escription
P 01
Enables automatic closing
P 02
Sets the automatic closing time
P 03
APCH input operation
P 04
Pre-flash
P 05
Instant closure
P 06
Logic of the STPA input
P 07
AUX output operating mode
P 08
Enables checking the safety
inputs
P 09
Slowdown distance when closing
P 10
Slowdown distance when opening From 100 to 0%
P 13
Opening deceleration speed
P 14
Closing deceleration speed
P 15
Motor force
P 16
Force on obstacle detection
(parameter can only be used with
encoder)
P 17
Braking
P 18
Gate opening direction
P 2 0
Selects the operation of the
second radio channel
P 2 1
Channel 2 output activation time
P 2 2
Pedestrian opening distance
P 2 4
Break-out on starting
P 2 5
Manned, APCH controls opening
by keeping the button pressed,
PED controls closing by keeping
the button pressed
28
Settab le v alues
ON/OFF
2-600 seconds
1= when opening, APCH input not active (condo)
2 = APCH as sequential (open, stop, close, open)
3 = APCH as sequential (open, close, open...)
4 = APCH commands only opening, APED commands only
closing
OFF= pre-flash off
ON= pre-flash on (flashing output activated for 3 seconds
before the movement of the gate)
ON= with the gate opening or open on disengaging the
PHOTO input (terminal 22) the gate closes 3 sec. after com-
pleting opening
OFF= normal operation
0= microswitch sensitive edge (the operation of this input
immediately reverses the movement for 1.5 seconds and then
stops the gate
1= resistive sensitive edge (balanced with 8.2Kohm resistance),
the operation of this input immediately reverses the movement
for 1.5 seconds and then stops the gate
2= photocell as internal protection (if engaged it stops the
gate, until it is disengaged, then it continues opening)
OFF = flashes slowly during gate opening and is on steady
when the gate is open and stationary, flashes rapidly during
closing and is off when the gate is closed and stationary
ON = flashes while the gate is moving and is off when the
gate is stationary
0 = input check off
1= check only on PHOTO input
2= check only on STPA input
3 = check on PHOTO and STPA inputs
From 0 to 100%
0%= no slowdown when closing
100% = slowdown for the whole closing distance
100%= no slowdown when opening
0% = slowdown for the whole opening distance
From 0 to 100%
0% = minimum slowdown speed
100% = maximum slowdown speed
From 0 to 100%
0% = minimum slowdown speed
100% = maximum slowdown speed
From 0 to 100%
0%= minimum force
100% = maximum force
From 0 to 100%
0% = minimum force (maximum obstacle sensitivity)
100% = maximum force (minimum obstacle sensitivity)
From 0 to 25
0 = minimum braking force
25 = maximum braking force
L = gate opening to the left
R = gate opening to the right
2CAN= activates the 2CH output
PEDO = controls pedestrian opening while the 2CAN output
functions as a courtesy light timed at 60 seconds
From 1 to 60 seconds
From 0 to 100% of total gate travel
OFF = gate starts with the force regulated with parameter
P15
ON = gate starts for 1 second at maximum power to then
return to the force regulated with parameter P15
OFF: function disabled
ON: function active if the safety devices are open (PHOTO
and STPA) gate starting is delayed by 3 seconds from actua-
ting the button
EN
D ef ault v alue
Modif ied
v alue
OFF
60 seconds
1
ON
OFF
0
OFF
0
30%
70%
45%
45%
50%
50%
5%
L
PEDO
1 sec.
50%
ON
OFF