Scope Of Delivery; Accessories - salmson PRIUX MASTER-D 32-90 Instalacion Y Puesta En Servicio

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

English
5.2
Technical data
Emission sound-pressure level
EMC
(electromagnetic compatibility)
Emitted interference
Interference resistance
Residual current I
1)
The pump is equipped with a power limiting function which provides protection against overload.
This can have an effect on the output depending on operation.
2)
See the following warning
CAUTION! Risk of injury and damage to property!
Non-approved fluids (see chapter 4) can destroy the pump and also cause personal
injury.
Comply strictly with the relevant safety data sheets and manufacturer specifications.
2)
Observe the specifications of the manufacturer regarding the mixing ratios.
2)
Add additives to the fluid on the pressure side of the pump.
Minimum inlet pressure (above atmospheric pressure) at the pump suction port in order to
avoid cavitation noises (at fluid temperature T
Nominal diameter
Rp 1
Rp 1¼
DN 32
DN 40
DN 50
DN 65
DN 80
DN 100
The values apply up to 300 m above sea level; allowance for higher altitudes:
0.01 bar/100 m increase in height.
5.3

Scope of delivery

Pump, complete
• Two flat gaskets
• Eight M16 washers and bolts for PN10
(for DN32-DN65 combination flanged version and DN80-DN100 flanged version)
• Installation and operating instructions
5.4

Accessories

Accessories must be ordered separately. For a detailed list, see the catalogue.
28
< 48 dB(A) (depending on the pump type)
General EMC: EN 61800-3
EN 61000-6-3
EN 61000-6-2
 3.5 mA (see also section 7.2)
T
Med
–20°C...+50°C
0.3 bar
0.3 bar
0.3 bar
0.5 bar
0.5 bar
0.7 bar
0.7 bar
0.7 bar
):
Med
T
Med
+95°C
1.0 bar
1.0 bar
1.0 bar
1.2 bar
1.2 bar
1.5 bar
1.5 bar
1.5 bar
T
Med
+110°C
1.6 bar
1.6 bar
1.6 bar
1.8 bar
1.8 bar
2.3 bar
2.3 bar
2.3 bar
Pompes Salmson 02/2013

Publicidad

Tabla de contenido
loading