4. Application
This pump's basic function is to pump hot or cold
water, water with glycol or other low viscosity
fluids that contain no mineral oil, solid or abrasive
substances, or materials having long fibres. The
manufacturer's approval is required for use to
pump corrosive chemicals.
DANGER! Risk of explosion!
Do not use this pump to handle flammable or
explosive liquids.
Application areas:
• water distribution and boosting installations
• industrial circulation systems
• process fluids
• cooling water circuits
• fire-fighting and washing stations
• watering installations, etc.

5. Technical data

5.1 Pump designation
NEXIS Advens 4 14 - F S
Verticale
multistages pump
in-line with high
hydraulic efficient
With high efficiency
Drive
(motor/converter)
3
Nominal flow rate in m
Number of stages
F: Flanges PN16
O: Flanges PN25
S: pump casing in stainless steel 304
+ hydraulic in stainless steel 304
X: pump casing in stainless steel 316L
+ hydraulic in stainless steel 316L
G: pump casing in cast iron
GJL-250 + hydraulic
in stainless steel 304
E : O rings EPDM (WRAS/KTW)
V : O rings VITON
KS : Cartridge seal
+ System orientation
POMPES SALMSON SAS 09/2013
5.2 Technical data
- Maximum operating pressure
• Pump casing:
• Maximum suction pressure: 10 bar
- Temperature range
• Fluid temperature:
• Ambient temperature:
- Electrical data:
• Motor efficiency:
• Frequency:
• Electrical voltage:
- Ambient humidity:
- Acoustic pressure level:
- Electromagnetic
compatibility
• residential emission -
1st environment:
• industrial immunity -
2st environment:
- Section of the power cable
(cable equipped of 4 wires):
E / KS
• 1,1kW :
• 2,2/3,2/4,2 kW :
• 5,5/6,5/7,5 kW :
(*) In the frequency range between 600 MHz and 1 GHz,
the display or the pressure indication in the display
might be disturbed in the direct vicinity (< 1 m from the
electronic module) of radio transmission installations,
transmitters or similar devices working in this frequen-
cy range. The functioning of the pump is at no time
affected.
Outline and pipe dimensions (Fig. 4).
Types
NEXIS Advens
2../4..
NEXIS Advens 6..
NEXIS Advens 10..
NEXIS Advens 16..

5.3 Scope of Supply

• Multistage pump.
• Installation and operating instructions.
• Counterflange + screws and o'rings for PN16
configuration.
• Counterflange bolts, nuts and gaskets for PN25
configuration.
25 bar
- 30°C to + 120°C
+ 50°C
>IE4
See motor plating
400V (±10%) 50Hz
380V (±10%) 60Hz
460V (±10%) 60Hz
< 90 % without
condensation
≤ 68 dB(A)
(*)
EN 61800-3
EN 61800-3
4 x 1,5 mm
4 x 2,5 mm
4 x 2,5 mm
2
4 x 4 mm
2
4 x 4 mm
dimensions (mm)
A
B
C
D
E
PN16
204 145 Rp1 2xM10
PN25
250 170 DN25 4xM12
PN16
204 145 Rp1
PN25
250 170 DN32 4xM16
320 462 440 410
PN16
248
175
PN25
280
PN16
248
185
PN25
300
English
2
min.
2
max.
2
min.
max.
F
G
H
J
1/4
2xM10
4xM12
Rp1
1/2
2xM12
DN40 4xM16
Rp2 2xM12
DN50 4xM16
33