Technical Data; Scope Of Delivery - salmson FVO 206 Serie Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

ENGLISH

5.2 Technical Data

Mains voltages
Mains frequency
Protection class
Nominal speed (50Hz)
Current consumption
Power consumption P
1
Nominal motor power P
2
Max. flow rate
Max. delivery head
1)
Operating mode S1
Operating mode: intermittent duty S3
Recommended switching frequency
Max. switching frequency
Nominal diameter of pressure port
Free ball passage
Max. submersion depth
Permitted temperature range of fluid
Noise level at min. level
Seal:
Oil filling:
Number of connections: (See section 7.2.1)
Power P
2
1.5 kW
Fuse in the power supply:
1)
Operation with a constant load until the machine can reach the thermal state of inertia.(acc. to DIN EN 60034-1)
2)
Operating time: 2.5 min., standstill time: 7.5 min. (within 10 min.)

5.3 Scope of delivery

Pump, depending on type, with:
•10 m replaceable electrical connecting cable (special lengths
on request)
– Single-phase type with condenser box
– Three-phase type with free cable end
•Installation and operating instructions
5.4 Accessories
Accessories have to be ordered separately:
•Switchgear for 1 or 2 pump operation
•External monitoring devices / tripping unit
•Level control (level sensor / float switch)
•Accessories for transportable wet sump installation
•Accessories for stationary wet sump installation
•Accessories for vertical dry sump installation
See the catalogue for a detailed list
Without cooling jacket
With cooling jacket
2)
on the fluid side
on motor side
Motor
1.5 kW; 1~ / 3~ 2 pole
2.5 - 4.0 kW; 2 pole
1.5 - 4.0 kW; Ex 2 pole
Oil type
Connections / h
10
20
1 ~ 230 V, ± 10 %, 3 ~ 400 V, ± 10 %
50 Hz
IP 68
See name plate
See name plate
See name plate
See name plate
See name plate
See name plate
Motor submerged
Motor on surface
Motor on surface:
25% in sumps up to max. ø3m, and 2.5m x 2.5m
6 1/h
20 times/h
See type key
Corresponds to nominal diameter DN [mm]
See name plate
+3 to 40 °C
< 70 db(A)
Mechanical seal SiC/SiC
Rotary shaft seal or
mechanical seal Cr-cast/carbon
Volume
150 ml
190 ml
230 ml
MARCOL 82 or comparable oils
Zmax (acc. to DIN EN / IEC 61000-3-11)
0.118 Ω
0.086 Ω
16 A, slow
15