Once the failing safety device is repaired, in automatic after 1 second, all standard
commands that were selected, such as step by step, automatic mode, radio commands and
automatic closing start functioning again.
Note 1: during this functioning in dead man mode, in case of damage to the safety strips
(or photocells) the photocells (or safety strips) still work by interrupting the operation
in progress.
The dead-man operation is only an emergency operation which must be activated for
a very short period and with the complete installation at sight so to have a secure and
safe control of the system.
As soon as possible however, the failing safety devices must be repaired and
activated.
BLINKER AND/OR FLASHING LIGHT (DIP5)
With DIP5 set ON =>
it is possible to connect a flasher
N.B.: This electric board can supply power ONLY TO
BLINKERS WITH (ACG7059) BLINKING CIRCUIT,
with max. 40W lamps.
With DIP5 set OFF =>
it is possible to connect a lamp for garage lighting (40 W max).
On every command input, the courtesy lamp will lit for 2 minutes. If during the 2 minutes
time, a second input is generated, the time elapsing will automatically restart for 2 minutes.
PRE-FLASHING FUNCTION
With DIP8 set OFF =>
the FLASHING LIGHT and the motor will start at the same time.
With DIP8 set ON =>
the FLASHING LIGHT starts working 3 seconds before every
movement of the motor.
AUTOMATIC CLOSING (DIP 3 ON)
The pausing time before the automatic closing is set during the "Time Programming".
In this case the maximum pausing time available is 5 minutes.
Pause time can be enabled or disabled by DIP3 (ON enabled).
RESTORING OF OPERATION FOLLOWING A POWER SHUT OFF
In case of power shut off the fence stops and the control unit will keep memory of the
interrupted motion.
On restoring of power a further command is necessary.
Upon command input the interrupted operation is completed (in case of opening, the open
stroke is completed...).

TECHNICAL DATA

Temperature range
Moisture
After having carried out the various connections and having supplied voltage, all the LEDS
are switched off.
The motor opens and closes, but it has no strength and moves slowly.
The shutter opens but does not close after the time set.
The shutter does not open or close by activating the various K and RADIO buttons.
By activating the K button the shutter does not move.
0±55°C
<95% without condensation
FAULT
Power supply voltage
Frequency
Transient power mains drops
Max. power managed at the motor output
Max. load at the blinker output
Max. card power absorption (excluding the accessories)
Current available for the photocells
Protection degree
Weight of the equipment
Dimensions
TECHNICAL FEATURES OF THE RADIO (CRX MODELS ONLY)
Frequency for the reception
Impedance
Sensitivity
Energizing time
De-energizing time
Codes to be memorized
Current available on the radio connector
- All inputs shall be used as clean contacts without earthing, because the power supply is
generated in the card and is structured in such a way to guarantee the respect of double
and reinforced insulation to the elements under voltage
- All inputs are managed by a programmed circuit that carries out a self-control every time
the door is operated.
TROUBLESHOOTING
After having carried out all connections, by carefully following the layout and having
positioned the gate in intermediate position, check the correct ignition of LEDS DL3, DL4.
In case of no ignition of the LEDS, always with gate in intermediate position, check the
following and replace any faulty components.
DL3 switched off
Faulty safety edge (In case the edge is not connected, carry out jumper
between COM and EDGE)
DL4 switched off
Faulty photocells
During functioning with personnel present, with DIP 1 at ON, check that during opening the
green DL7 LED switches on and that during closing the red DL6 LED switches on.
If not, invert clamps V and W on the motor terminal board.
Check the integrity of fuses F1 and F2.
In case of interrupted fuse use only of adequate value
Check trimmer TORQUE adjustment.
Ensure to have set DIP 3 at ON.
Button K BUTTON always inserted in automatic functioning mode (DIP 6 OFF).
Replace button or switch of the selector switch.
Failed edge self-test => check the connections between electronic board and edge feeder.
Attention: if not using a feeder for edges, DIP 10 must be at OFF position.
Faulty safety edge contact.
Faulty photocells contact with DIP 4 OFF.
Fix or replace the relative contact.
Impulse K always inserted.
Check and replace any buttons or micro-switches of the selector switch.
19
230V±10% (120V±10% on request)
50/60Hz
20ms
1CV
40W with resistive load
20mA
0,4A±15% 24Vdc
IP54
0,70 kg
14,7 x 6 x 18,5cm
433,92MHz
52ohm
>2,24µV
300ms
300ms
N° 60
200mA 12Vdc
SOLUTION
F2 = 5A
F1 = 100mA.