label, or the Tech Sheet that is located under the
front of the refrigerator.
NOTE
• To remove any remaining tape or glue, rub the
area briskly with your thumb. Tape or glue
residue can also be easily removed by rubbing a
small amount of liquid dish soap over the
adhesive with your fingers. Wipe with warm
water and dry.
• Do not use sharp instruments, rubbing alcohol,
flammable fluids, or abrasive cleaners to remove
tape or glue. These products can damage the
surface of your refrigerator.
• Reinstall or adjust shelves as needed.
Refrigerator shelves are installed in the shipping
position. Reinstall shelves according to your
individual storage needs.
Choosing the Proper
Location
Water
Must be located where a water supply can be
connected for the automatic icemaker.
NOTE
• The water pressure must be 20 - 120 psi or 138 -
827 kPa or 1.4 - 8.4 kgf/cm
installed in an area with low water pressure
(below 20 psi or 138 kPa or 1.4 kgf/cm
install a booster pump to compensate for the
low pressure.
Dimensions and Clearances
• Check the dimensions of the appliance and the installation path to ensure there is sufficient room to
move the refrigerator through doors or narrow openings.
• If an opening is too narrow to fit the refrigerator through, remove the refrigerator doors. See Removing/
Assembling the Doors and Drawers in this manual.
• The installation location chosen for the refrigerator should allow space behind the unit for connections
and airflow and space in front to open the doors and drawers.
2
. If the refrigerator is
2
), you can
Electricity
Use an individual, grounded outlet:115 Volts, 60
Hz, AC, 15 Amps minimum.
WARNING
• Do not overload house wiring and cause a fire
hazard by plugging in multiple appliances in the
same outlet with the refrigerator.
• To reduce the risk of electric shock, do not install
the refrigerator in a wet or damp area.
Flooring
To avoid noise and vibration, the unit must be
installed and leveled on a solidly constructed floor.
If required, adjust the leveling legs to compensate
for the unevenness of the floor.
NOTE
• Installing on carpeting, soft tile surfaces, a
platform or weakly supported structure is not
recommended.
Ambient Temperature
Install this appliance in an area where the
temperature is between 55 °F (13 °C) and 110 °F
(43 °C).
If the temperature around the appliance is too low
or high, cooling ability may be adversely affected.
INSTALLATION
11