Descargar Imprimir esta página

Festo CPV GE ASI-8E8A-Z M8 Serie Manual Del Usuario página 30

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 31
Type CPV..−GE−ASI−8E8A−Z M8
AS−Interface bus connection
Voltage range (protected against incorrect
polarity)
Residual ripple
Max. current consumption at − 5 °C
all inputs 0−status
all inputs 1−status, no current
consumption by sensors (e.g. switches)
all inputs 1−status, max.
current consumption by sensors
Load voltage connection
Rated value (protected against incorrect
polarity)
Residual ripple
Current consumption for 8 valves
when switched on (26.4 V)
when switched on (20.4 V)
after current reduction (stationary; 26.4 V)
after current reduction (stationary; 20.4 V)
Valves (see pneumatics manual)
Digital inputs
Design
Logic level
Reference potential
Response delay
1)
E.g. per input 30 mA, incl. 7 mA for input circuit
2)
For max. 30 ms, all valve coils switched simultaneously
30
1)
2)
2)
Festo CPV..−GE−ASI−8E8A−Z M8 0306c English
26.5 ... 31.6 V DC
20 mVpp
CPV10−... CPV14−...
40 mA
40 mA
96 mA
96 mA
278 mA
278 mA
21.6 ... 26.4 V DC
4 Vpp
CPV10−... CPV14−...
200 mA
310 mA
160 mA
210 mA
70 mA
100 mA
90 mA
120 mA
Watchdog function
active after approx.
40 ... 100 ms
(see 3.6)
8 digital inputs
based on IEC 1131−2
type 2
24 V DC, PNP,
Status display (LED)
ON:
11 ... 30 V DC
OFF: −30 ... 5 V DC
0 V DC
Typ. 3 ms (at 24 V)

Publicidad

loading

Este manual también es adecuado para:

Cpv ge serieCpv ge-asi-8e8a-z m serie