help" device for about 15 seconds. The call indicator (bells,
buzzers, lamps, etc.) can be powered either with 220/240V or
low voltage, but with a maximum current absorption of 10A.
The alarm connection must be carried out by using a cable with
no lesser characteristics than a type H 05 VV-F 2x2.5 mm
is essential to use this cable, to ensure that the cable clamp fit-
ted on the box has the degree of protection (waterproofness) re-
quired by regulations.
N.B. The cable clamp for the alarm exit is closed by the man-
ufacturer with a cap, which must only be removed if the
"ALARM" connection is made.
I (detail 4) Unwind the cable of the temperature probe and fas-
ten it to the panel, at the top, using the ring nut.
I (detail 5) Make the equipotential connection of the shower
box using the terminal provided on the frame, as shown.
Installation of equipped panel
i
I (
15 detail 1) Place silicon in the indicated position.
i
I (
15 detail 2-3) Then insert the equipped panel in the
groove of the seat-structure (vertical) and in the one on the tray
(horizontal); then proceed with fastening of the indicated screws
and washers.
i
I (
15 detail 4-5) Connect the hose to the union located on
the panel and then to the shower head, placing respectively the
gasket and the filter.
i
I (
15 detail 6) Place two beads of silicon as shown (in the
spaces between the gasket and the vertical wall of the seat
structure).
Glass panel installation
and of the hydraulic crosspiece
i
I (
16 detail 1) Take the long glass panel and apply the
gasket to its lower side.
i
I (
16 detail 2) Then insert the glass panel in the compensator.
NB: check that the profile of the glass panel and the com-
pensator match perfectly (detail 3).
i
I (
17) Fasten the glass panel to the shower tray as shown:
- (detail 1-2): from inside, attach bracket "T", which must be
fastened to the shower tray as shown.
- (detail 3-4): from outside, attach block "T2", which must be
fastened from the inside as shown (detail 4), without tight-
ening the screw completely.
i
I (
18 detail1) Place silicon on the indicated zone.
i
I (
18 detail 2) Take the short glass panel and apply the in-
dicated gasket to its lower side.
i
I (
18 detail 3) Then insert the glass panel in the compensator.
NB: check that the profile of the glass panel and the com-
pensator match perfectly (detail 4).
i
I (
19) Fasten the glass panel to the shower tray as shown:
- (detail 1-2): from inside, attach bracket "T", which must be
2
. It
fastened to the shower tray as shown.
- (detail 3-4): from outside, attach block "T2", which must be
fastened from the inside as shown (detail 4), without tight-
ening the screw completely.
- (detail 5): further fasten the glass panel to the profile of the
panel, as shown; first insert the plastic bush "U" in the hole
on the glass panel.
Installation of the hydraulic crosspiece
i
I (
20 detail1a-1b-2) Fasten the crosspiece to the panel
and, temporarily, to the glass panel.
Place plate "P" on the outside between the glass panel and the
screws.
i
I (
20 detail 3a-3b-3c) Insert the lighting cables in the hole
in the panel, then place the lighting box near the fastening brack-
et (seat). Fasten the light box to the bracket and make the elec-
trical connection to the junction box located under the seat, as
shown.
i
I (
20 detail 4a-4b) Run tube "M" (from the mixing group,
i
see
13) through the hole on the crosspiece and connect it
to the hose of the shower head, locking it in place with a plas-
tic clamp.
i
I (
20 detail 5-6-7) Once you have adjusted the perpen-
dicularity of the glass panel, fasten the crosspiece permanent-
ly and apply the cylindrical covers.
i
I (
20 detail 8) Apply the cover to the crosspiece.
Fastening of glass panels
i
I (
21 detail 1) Drill the profile of the glass panel, using as
a reference the holes already present on the compensator and
fasten the two elements as indicated.
i
I (
21 detail2-3) Apply the gasket, as indicated, using the
appropriate tool. Then place a bead of silicon on the tray in the
indicated zone.
i
I (
22 detail 1) Drill the glass panel-upright, using as a ref-
erence the holes already present on the compensator and fas-
ten the two elements as indicated.
i
I (
22 detail 2) Cut the gasket to size and apply it as shown.
i
I (
22 detail 3) Apply the gasket between the shelf and the
structure of the seat, and then cut off the part in excess. Where
indicated, make cuts (only on the part to be inserted between the
shelf and seat) so as to make it easier to fold the gasket at a
right angle.
i
I (
23 detail1-2) Completely lock the plates "T" as shown
and then press in the covers.
10