0,6 m
Connection to the electrical system of the building must be made us-
ing a sheathed cable that is not less than H 05 VV-F 3x2,5 mm
The electric system of the building must be e-
quipped with a 0.03 A differential switch.
Ω
mega shower boxes are equipped with a connection terminal, lo-
cated in the central part of the frame, marked with the symbol
for equipotential connection of surrounding metal parts, as requi-
red by EN 60335-2-105 norms; we recommend that the relevant
connection cable comes out in position 2.
The appliance comes equipped with an LED lighting system, in com-
pliance with Regulation EN 62471:2009.
CAUTION! Before carrying out any maintenance op-
eration, disconnect the appliance from the power
supply line.
JACUZZI EUROPE S.p.A. shall not be held liable:
If installation is carried out by unqualified personnel and/or per-
sonnel unauthorized to carry out installation.
If the norms and legal provisions, regarding the electric systems
of buildings, in force in the country in which installation is carried
out are not complied with.
If the instructions for installation and maintenance contained in this
manual are not followed.
If unsuitable and/or uncertified materials are used for installation.
If the shower enclosures are set up to work without conforming
to the aforesaid regulations.
If incorrect operations are performed that reduce the level of
protection of the electrical equipment against water jets, modify
the protection against electrocution due to direct or indirect con-
tact, or produce abnormal conditions of insulation, current leak-
age or overheating.
If any components or parts of the appliance are altered in relation
to the original state when supplied, releasing the Manufacturer from
any liability.
If the appliance is repaired by unauthorised personnel or if spare
parts are used other than the original ones supplied by Jacuzzi Eu-
rope S.p.A.
CLEANING THE THERMOSTATIC VALVE
The thermostatic valve is provided with mesh filters to trap any
impurities in the water. Over time, these filters could become
0,6 m
clogged and, therefore, inhibit the functions of the mixer tap.
To clean the valve, remove it in this way:
I Turn off the water supply (hot and cold) to the box.
I (
diverter dial (g) to the symbol "2 bottom jets" and turning on
the stop tap (R) completely. Then turn off the stop tap again,
turning the dial to the previous position.
2
.
I (
screwdriver as a lever if necessary.
I (
I (
,
er dial (S).
I (
ring and the cylinder.
Clean the mesh filters with a little brush and rinse. If scale is p-
resent, wash with specific products.
Replace the various components following the same procedure
in reverse order. Make sure that you correctly put back the stop
tap dial (R).
I (
(Q) is facing downwards, and that it fits into the groove of the
brass component.
12
i
1) Empty the water from the mixer unit, by turning the
i
2-3) Remove the cap (M) from the mixer dial, using a
i
4-5) Remove the screw (V) and ease out the dial (M).
i
6-7) Unscrew the cover (N) and then remove the mix-
i
8) Ease out the thermostatic valve (T) with the brass
i
9) Fasten the thermostatic valve so that the screw peg