Update notice
Code: 3AUA0000121717 Rev D.
Valid: From 2013-01-07 until revision F of these PVS800-57 hardware manuals:
Manual code
3AUA0000053689
3AUA0000083886
3AUA0000097080
3AUA0000083887
3AUA0000083888
3AUA0000125276
English manual (code 3AUA0000053689, revision E)
Page
Correction
107
Power factor (cos phi
Types -0315kW-B and -0630kW-B
Q
=
0.9 · 10 000 - P
max
Revision
Language
E
English
E
German
E
Spanish
E
French
E
Italian
E
Russian
) adjustment range
1
2
act
Addition to page 115
EN
Applicable standards and requirements
VDE-AR-N 4105
DE
The inverter complies with IEC 61000-3-12
ES
when its output power is 20% of the nominal
FR
power or greater. When the output power is less
IT
than 20% of the nominal power, the R
is 250.
RU
Q
= 0.9 ·
10 000 - P
max
sce
2
act
value