Beginning work with the machine
Attention:
Always wear slip-resistant shoes and ap-
propriate working clothes when working
with this machine!
Attention:
Start familiarization with the machine by
making your first driving attempts in a free
area.
Cleaning start
• Insert the plug into the mains socket.
The display lights up.
• Switch the suction unit on.
• Use the single-disc machines as described in the ergodisc
165/175/200/238/300/400/438/duo or ergodisc 1200 man-
ual.
End of operation
• Release the operating lever.
• Switch the suction unit off.
• Remove the plug from the mains socket.
Attention:
The machine must now be emptied and
cleaned. Switch off the machine (main
switch) and remove the plug from the
mains socket.
Removing/cleaning the suction skirt
• Remove the suction hose.
• Remove the tool as described in the ergodisc 165/175/200/
238/300/400/438/duo or ergodisc 1200 manual.
Replacing the double filter paper bag
Notice:
Wait a moment for the dust to settle before
you remove the double filter paper bag.
• Press the adjusting lever and lift the
guide bar upwards slowly until it is
completely upright.
• Release the adjusting lever to lock
the guide bar.
• Remove the power supply cord of the
device from the power socket of the
single-disc machine.
• Release the holding bar (1) and re-
move the device from the holder of
the single-disc machine.
1
• Press the release switch and remove
the suction unit cover.
• Push the double filter paper bag
down slowly.
Notice:
The full double filter paper bag must be
disposed of in compliance with national
regulations.
Inserting the double filter paper bag
Notice:
The motor protection filter must be
cleaned or replaced after every third re-
placement of the double filter paper bag
(for cleaning/replacing the motor protec-
tion filter, see page 38).