Start-up and use
OPERATING MODES
STANDARD MODE
In this operating mode, only the power cord is connected to the appliance.
The temperature is constantly regulated by the thermostat to the level set from the oper-
ator panel and indicated by LEDs 1-2-3, with an error margin of ± 1° C (see temperature
settings table).
TIMER MODE
In this operating mode, only the power cord is connected to the appliance.
The appliance operates only within the temperature ranges set using the remote control
and the temperature is constantly regulated by the thermostat to the level set from the
operator panel and indicated by LEDs 1-2-3, with an error margin of ± 1° C (see temper-
ature settings table).
USING THE REMOTE CONTROL
Open
P1
P2
P3
P4
-
+
SET
ON
OFF
189A1018
The appliance comes with a remote control unit that allows the user to set the compressor
to operate at certain times of the day. Each refrigerator has three pre-set operating peri-
ods and one (P4) that can be programmed by the user. A maximum of two on/off cycles
can be set every 24 hours. The remote control is easy to use. Once you have selected the
programme from the remote control, simply point it at the receiver to the right of the con-
trol panel (from a distance of about 30-40 cm). Press and hold the button of the selected
programme on the remote control for at least two seconds: the appliance switches on.
The display will show the following symbol.
25