Filter Removal & Installation; Removal And Installation Of The Qwik Lock™ Filter - Workshop WS0600VA0 El Manual Del Propietario

Ocultar thumbs Ver también para WS0600VA0:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SP6863 Workshop 6 9 GALLON
FILTER REMOVAL & INSTALLATION
Removal and Installation
of the Qwik Lock™ Filter
Filter Removal:
1. Hold the Filter tabs of the Qwik Lock™
Filter in each hand.
2. With one thumb on the Qwik Lock™
stud, which protrudes through the
integrated Filter plate, lift up on the
Filter tabs while pushing down on the
stud.
3. This action will cause the Filter to
release from the Filter cage. Slide
Filter off cage.
Filter Installation:
1. Carefully slide the Qwik Lock™ Filter
over the Filter cage and press down
on the outside edge of the Filter until
the rubber gasket on the bottom of the
Filter seats securely around the base
of the Filter cage and against the lid.
2. Align the small center hole in the top
of the Filter over the Qwik Lock™ stud
on the Filter cage. Press firmly on top
of the Filter near the stud to allow the
Filter to snap over the ball on the end
of the stud. The Filter is now attached.
NOTE: Failure to properly seat the
bottom gasket could result in debris
bypassing the Filter.
!
WARNING: Do not operate
without Filter cage and float, as they
prevent liquid from entering the
impeller and damaging the motor.
7/27/12
2:01 PM
Integrated Filter
Plate with Center
Hole
Lid
5
Page 5
PUSH
DOWN
Filter
Tabs (2)
Filter
Cage
PULL
UP
Rubber
Gasket at
Bottom of
Filter
(cutaway
view)
Qwik
Lock™
Stud

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Ws0900va0