Displays
Pos.
Colour
MS
Green
EN
Yellow
ME
Red
PS
Red
DE
Red
EDK94AYAD DE/EN/FR/ES/IT 2.0
State
Description
On
Drive-based safety is initialised faultlessly.
Drive-based safety is initialised faultlessly. Internal
Blinking
communication to the standard device is not possible.
Off
Drive-based safety is not initialised.
Acknowledgement is not possible.
On
Controller enabled
Off
Non-safe display "STO"
System error:
After a serious internal error, STO is activated.
On
Can only be reset by switching the 24V supply.
Error:
After an internal error or an error at the safe
inputs, a standstill function is activated.
Blinking
The safety class is quit.
Acknowledgement is possible.
Fault:
A monitoring function has responded and
activated a standstill function.
Flashing
The safety class is not quit.
Acknowledgement is possible.
Off
Error-free operation
Error PROFIsafe:
Communication is not possible.
On
Acknowledgement is possible.
Blinking
No valid PROFIsafe configuration
Off
PROFIsafe is error-free.
The module is not accepted by the standard device
(see notes given in the documentation for the
On
standard device).