Sanus VMT35 Manual De Instrucciones página 7

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 14
2 Mount the Wall Plate
Solid concrete or concrete block
2-1 Mark the wall
2-2 Drill pilot holes
2-3 Insert anchors and lag bolts
[06]
6901-002150 <00>
[01]
[06]
[05]
[04]
For assistance in determining wall plate location, see Height Finder at
sanus.com.
Level the wall plate [01] and mark the hole locations.
CAUTION:
Avoid potential injuries or property damage!
Mount the wall plate [01] directly onto the concrete surface.
Minimum solid concrete thickness: 203mm (8 in.).
Minimum concrete block size: 203 x 203 x 406 mm (8 x 8 x 16
in.).
Minimum horizontal space between fasteners: 406 mm (16 in.).
CAUTION:
Avoid potential injuries or property damage!
Pilot holes MUST be drilled to a depth of 75 mm (3 in.) using a
10 mm (3/8 in.) diameter drill bit.
Never drill into the mortar between blocks.
75 mm
(3 in.)
Insert lag bolt anchors [06]. Then insert lag bolts [04] through the
washers [05], wall plate [01], and into the anchors [06].
CAUTION:
Improper use could reduce the holding power of
the lag bolt. To avoid potential injuries or property damage:
Be sure the anchors [06] are seated flush with the concrete
10 mm
13 mm
(3/8 in.)
(1/2 in.)
surface.
Tighten the lag bolts [04]
only until the washers [05]
[01]
are pulled firmly against the
wall plate [01].
DO NOT over-tighten the lag
bolts [04].
7

Publicidad

Tabla de contenido
loading

Tabla de contenido