Time since last full charge: The number of days since the last full charge.
Synchronisations: The number of automatic synchronisations. A synchronisation is counted every time the
state of charge drops below 90% before a synchronisation occurs.
Number of full discharges: The number of full discharges. A full discharge is counted when the state of
charge reaches 0%.
Battery voltage
Min battery voltage: The lowest battery voltage.
Max battery voltage: The highest battery voltage.
Min starter voltage: The lowest auxiliary battery voltage (if applicable).
Max starter voltage: The highest auxiliary battery voltage (if applicable).
Voltage alarms
Low voltage alarms: The number of low voltage alarms.
High voltage alarms: The number of high voltage alarms.

5.6 Trends

The "Trends" section of VictronConnect enables datalogging, but only while VictronConnect is connected and
communicating with the SmartShunt. It will simultaneously log two of the following parameters: voltage, current,
power consumed Ah or state of charge.

5.7 LED status codes

The SmartShunt has two LEDs, a Bluetooth status LED (blue), and an error LED (red). These LEDs are both
associated with the SmartShunt Bluetooth interface.
On power-up, the blue LED will blink, and the red LED will quickly flash. The red LED will give a short flash to
confirm that the red LED is functional.
When the blue LED is blinking the SmartShunt is ready to be connected to VictronConnect.
When the blue LED is stays on, the SmartShunt has successfully connected to VictronConnect via Bluetooth.
When the blue and the red LEDs are alternating blinking the SmartShunt firmware is being updated.