CONTROL BOARD FOR T-ONE5B GEARMOTOR
MICROPROCESSOR-CONTROLLED LOGIC
INPUT STATUS LED'S
LINE INPUT FUSE
"PEDESTRIAN GATE" FUNCTION
BUILT-IN FLASHING LIGHT CIRCUIT
433.92 MHz 2 CHANNEL BUILT-IN RADIO RECEIVER (CH)
BATTERY CHARGER BOARD (INTEGRATED)
BATTERY CONNECTOR
ENCODER SENSOR FOR OBSTACLE DETECTION AND SELF-LEARNING OF TRAVEL
ADJUSTABLE DECELERATION
DIAGNOSTICS OF MALFUNCTIONS SIGNALLED BY LED
EN COMPLIANT AND CERTIFIABLE UP TO 500 KG LEAF
ATTENTION:
-
do not use single cables (with one single wire), ex. telephone cables, in order to avoid
breakdowns of the line and false contacts;
-
do not re-use old pre-existing cables.
TESTING
When you have completed the connection:
All the green LEDs must be on (each of them corresponds to a Normally Closed input). The go off
only when the controls to which they are associated are operated.
All the red LS LEDs must be off (each of them corresponds to a Normally Open input). The light up
only when the controls to which they are associated are operated. Except for the DL3 diagnostics
led which must always be on.
TECHNICAL CHARACTERISTICS
Board power supply
Max motor power DC
Fast acting fuse for protection of input power supply 13.5 Vac (F1 - 5x20)
Fast acting fuse for motor protection (F2 - 5x20)
Fast acting fuse for protection of auxiliary circuits 18 V dc (F3 - 5x20)
Fast acting fuse for protection of battery (F4 - 5x20)
Motor power supply circuits voltage
Auxiliary device circuits supply voltage
Logic circuits supply voltages
Operating temperature
Box protected to
DIAGNOSTICS LED
DL1 (PEDESTRIAN)
DL2 (OPEN/CLOSE)
DL3 (ERR)
DL4 (STOP)
DL5 (PHOTO)
DL6 (SENSITIVE EDGE)
DL7 (TENSION)
14
PEDESTRIAN button red LED signal
OPEN/CLOSE button red LED signal
ERRORS red LED signal
STOP button green LED signal
PHOTOCELL green LED signal
SENSITIVE EDGE green LED signal
POWER ON (also battery voltage) green
K125M
English
13,5 Vac - 50 Hz
50 W - 18 Vdc
F 16 A
F 10 A
F 2 A
F 10 A
18 Vdc
18 Vdc
5 Vdc
-20 °C ÷ +70 °C
IP 44
LED signal