Operation; Pre-Start Checklist; Shutdown; Maintenance - Senco PC2017 Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Pre-start cHecKlist:

. Check oil level. Add if necessary.
2. Remove any moisture in the air compressor air tank. Remove excessive pressure with an air tool, then open
the air tank drain valve in the bottom of the air tank. Close tightly when drained.
risk of bodily injury. neVer attempt to open the drain valve when more than 10 Psi of air
pressure is in the air tank!
3. Make sure the engine switch is in the "OFF" position.
4. Make sure all safety valves are working correctly.
5. Make sure all guards and covers are in place and securely mounted.
start-uP: Read safety warnings before performing operation.
. Flip the toggle on top of the pilot valve to the upright position. This provides a loadless start. The air compressor
will unload and allow the engine to start easier.
2. Start the engine. (Refer to the Engine Manual accompanying this unit.)
3. When the engine has run for 1-2 minutes, flip toggle back to the original position.
4. Set pressure by adjusting the pressure regulator knob counterclockwise for less pressure and clockwise for
more pressure.
5. If you notice any unusual noise or vibration, stop the air compressor and refer to "Troubleshooting".

sHutdoWn:

. To stop the air compressor, move the engine switch to the "Off" position. (Refer to the Engine Manual
accompanying this unit.)
2. Drain air from the air tanks by releasing air with an attached air tool or by pulling on the safety relief valve
rings.
3. Once pressure in the air tanks register under 0 pounds, open the drain valve under each air tank to drain any
moisture.
4. Allow the air compressor to cool down.
5. Wipe air compressor clean and store in a safe, non-freezing area.
Read the instruction manual before performing maintenance. The following procedures must be performed when
stopping the air compressor for maintenance or service.
. Turn off air compressor.
2. Open all drains.
3. Wait for the air compressor to cool before starting service.
PROCEDURE
Check pump oil level
Check engine oil level
Check engine air filter
Oil leak inspection
Drain condensation in air tank(s)
Inspect guards/covers
Check for unusual noise/vibration
Check safety relief valve
Inspect air filter
Clean exterior of compressor
Inspect belt
Check for air leaks
Change pump oil *
Replace air filter
Check engine spark plug
*The pump oil must be changed after the first 50 hours of operation and every 200 hours or 3
months, whichever comes first.
Senco
Gasoline Air Compressor Manual 2005
®

oPeration

Warning

Maintenance

Maintenance cHart

DAILY
WEEKLY
X
X
X
X
X
X
X
X
X
X
MONTHLY
200 HOURS
X
X
X
X
X


Publicidad

Tabla de contenido
loading

Tabla de contenido